[編碼器] [接近傳感器] [光電傳感器] [壓力傳感器] [溫度傳感器] [濕度傳感器]
[氣流傳感器] [液位流量傳感器] [磁性傳感器] [霍爾效應(yīng)傳感器] [線性位移傳感器]
傳感器 | |
|
Part No.AL-1000-3-T90AX-E-25-P30 EEX IAAX-E-56-P30-GFAX-S-25-P30 EEX IAAX-S-56-P30-GFILD-201-E ILD-201-S IRD-10N/P-GDIRD-10PIRD-10RAIRD-10RA-IIRD-10-XCIRD-15N/P-GDIRD-25N/P-GDIRD-15-XCIRD-2A IRD-2A-I IRD-4A-I IRD-2N/P-GDIRD-30N/P-GDIRD-4A IRD-4N/P-GDIRD-5-XCIRD-TDIRF-04XIRF-15X IRF-1X IRF-2X IRF-30XIRF-4X IRG-10IRG-4X-Z2 S13IRL-225A-E-VA-24 VDCIRL-225A-S-24 VDCIRL-235A-E-VAIRL-55N-E-GF-24 VDCIRN-10N/P-GDIRN-10-XC-GDIRN-15N/P-GDIRN-15-XC-GDIRN-25N/P-GDIRN-2N/P-GDIRN-30N/P-GDIRN-4N/P-GDIRN-5-XC-GDIRN-U-TD-GD IRS-10N-GFIRS-10P-GFIRS-10-XCIRS-15-XCIRS-2N-GF IRS-2P-GF IRS-30N-GFIRS-30P-GFIRS-4N-GFIRS-4N-GF IRS-4P-GFIRS-5-XCIRS-U-10N/PIRS-U-10RAIRS-U-10RA-IIRS-U-15N/PIRS-U-25N/PIRS-U-2AIRS-U-2A IRS-U-2A-I IRS-U-2N/PIRS-U-30N/PIRS-U-4A IRS-U-4A -24 VDCIRS-U-4A-I IRS-U-4N/PNEX-112-ENEX-112-R
煤礦用風(fēng)筒風(fēng)量開關(guān)傳感器 煤礦井下風(fēng)筒內(nèi)風(fēng)量測量儀 通風(fēng)機(jī)風(fēng)筒內(nèi)風(fēng)量檢測儀
型號:HJ19-KGV6
KGV6型煤礦用風(fēng)筒風(fēng)量開關(guān)傳感器
KGV6型煤礦用風(fēng)筒風(fēng)量開關(guān)(以下簡稱風(fēng)筒風(fēng)量開關(guān)),屬礦用本質(zhì)安全型設(shè)備,可用于煤礦井下有爆炸性氣體的環(huán)境。風(fēng)筒風(fēng)量開關(guān)無需供電,主要用于檢測煤礦井下掘進(jìn)工作面或采煤工作面局部通風(fēng)機(jī)風(fēng)筒內(nèi)的風(fēng)量是否充足。當(dāng)風(fēng)筒內(nèi)的風(fēng)量充足時,活動支架展開致使機(jī)械按鈕開關(guān)動作,并輸出無源觸點(diǎn)信號供外接設(shè)備的采集?捎行У販p少因風(fēng)筒內(nèi)風(fēng)量小、風(fēng)筒出現(xiàn)漏風(fēng)或風(fēng)機(jī)發(fā)生故障而造成的安全事故。風(fēng)筒風(fēng)量開關(guān)除了和KJ70型煤礦安全生產(chǎn)監(jiān)控系統(tǒng)配合使用外還能夠和國內(nèi)其它的煤礦監(jiān)測系統(tǒng)相兼容。
使用環(huán)境
* 環(huán)境溫度:0℃~40℃
* 平均相對濕度:不大于95%(+25℃)
* 大氣壓力:80kPa~106kPa
* 無顯著振動和沖擊的場合
* 煤礦井下有爆炸性混合物,但無破壞絕緣的腐蝕性氣體的場合
技術(shù)參數(shù)
* 輸出接點(diǎn)接觸電阻:應(yīng)小于1Ω(常開,常閉接點(diǎn)各組)
* 輸入本安直流信號:電流小于10mA,電壓小于18V(來自監(jiān)控分站或控制主機(jī))
a.KJF31.1型監(jiān)控分站
b.KHJ6.1型控制主機(jī)
* 信號大傳輸距離:2km;(采用煤礦用聚乙烯絕緣聚氯乙稀護(hù)套通信軟電纜MHYVR:分布電阻≤12.1Ω/km,分布電容≤0.06μF/km,分布電感≤0.8mH/km)
* 風(fēng)筒允許直徑:∮400mm
鉑電阻溫度傳感器,分為裝配式鉑電阻和鎧裝式鉑電阻。裝配式鉑電阻由外保護(hù)管,延長導(dǎo)線,測溫電阻,氧化鎂裝配而成,產(chǎn)品體積小巧,結(jié)構(gòu)簡單,反應(yīng)靈敏,防水抗震等特點(diǎn);鎧裝鉑電阻由電阻體,引線,絕緣氧化鎂及保護(hù)管整體拉制而成,產(chǎn)品結(jié)構(gòu)復(fù)雜,響應(yīng)速度更快,抗震性能更好,測溫更寬,且可彎曲等特點(diǎn),均可廣泛用于環(huán)境,液體,冷凍冷藏,電機(jī)軸瓦等多種行業(yè)的溫度測量!WZP系列溫度傳感器選型: a、確定溫度傳感器的類型; b、實(shí)際使用溫度范圍; c、精度、尺寸及安裝固定方式; d、螺紋規(guī)格,導(dǎo)線線制等等
BSQ-10傳感器信號放大器將傳感器配一小信號精密放大線路,線路內(nèi)部穩(wěn)壓,恒流供橋、電壓電流轉(zhuǎn)換,阻抗適配,線性補(bǔ)償,溫度補(bǔ)償?shù),將力學(xué)量轉(zhuǎn)換成標(biāo)準(zhǔn)、電流、電壓信號輸出,4~20mA、0~10mA、0~5V、1~5V直接與自動控制設(shè)備接口或與計(jì)算機(jī)聯(lián)網(wǎng),變送器具備標(biāo)準(zhǔn)信號外調(diào)零,外調(diào)增益功能。
主要技術(shù)指標(biāo)
輸入:
mV級電壓信號輸出: 1.5 mV/V 或 0~5V,1~5V,0~10mA,4~20mA 0-20mA
激勵電壓: 10V 或 12V,15V,24V(DC)工作溫度: -20~70 oC
型號 | 外形 | 通道數(shù) | |
BSQ | 2 | 1 | 1通道 |
10 | 2 | 2通道 | |
10 | 3 | 3通道 | |
10 | 4 | 4通道 |
選型
變送器接線端子
變送器輸入端:
1——傳感器電源+(紅)
2——傳感器電源-(綠)
3——傳感器信號+(黃)
4——傳感器信號-(白)
5——屏蔽層
變送器輸出端:
1——電源+(紅)
2——電源-(綠)
3——信號+(黃)
變送器的尺寸
長150*寬*100*高44
梅特勒托利多稱重傳感器
適用于支撐型儲罐和輸送滾道,集成了安全保護(hù)裝置。具有 OIML、 NTEP 以及危險區(qū)域應(yīng)用的全球認(rèn)證。 |
適用于懸掛式儲罐和料斗,集成了安全保護(hù)裝置。具有OIML、 NTEP 以及危險區(qū)域應(yīng)用的全球認(rèn)證。 | |||||
高速、高精度的稱量模塊。度身定做,以滿足設(shè)備或機(jī)器制造商進(jìn)行簡單組合的需求。 |
量程從幾千克到幾噸。具有OIML、NTEP全球計(jì)量認(rèn)證和危險區(qū)域應(yīng)用的ATEX、 FM防爆認(rèn)證。 | |||||
適用于包括動態(tài)應(yīng)用在內(nèi)的汽車衡與軌道衡。 |
稱重范圍最大達(dá)到幾百噸。具有OIML、NTEP全球計(jì)量認(rèn)證和危險區(qū)域應(yīng)用的ATEX、 FM防爆認(rèn)證。 | |||||
量程從幾百千克到幾十噸。具有OIML、NTEP全球計(jì)量認(rèn)證和危險區(qū)域應(yīng)用的ATEX、 FM防爆認(rèn)證。 |
量程從幾十千克到幾噸。具有OIML、NTEP全球計(jì)量認(rèn)證和危險區(qū)域應(yīng)用的ATEX、 FM防爆認(rèn)證。 | |||||
量程從幾千克到幾噸。四角偏差做過補(bǔ)償,適用于臺秤、小噸位料罐稱重。 |
配有數(shù)字電子元件,可直接連接上部系統(tǒng)并提供過程控制功能。 | |||||
適用于溫度高達(dá)200°C 的環(huán)境。特殊高溫材料選取以及精密制作工藝傳感器在極端環(huán)境下獲得的穩(wěn)定性。 |
輕松實(shí)現(xiàn)多個稱重傳感器與稱重儀表的連接。ATEX 型適用于危險區(qū)域。 |
SB-5,SBF-11.25 GD-15 GD-20 GD-30 GD-50剪切梁式傳感器:SBC-0.5 SBC-1 SBC-2 SBC-3 SBH-0.25 SBH-0.5 SBH-1 SBH-2 SBH-3 SBH-5SBS-250 SBS-500 SBS-1000 SBS-2000 SBS-5000 SBT-0.5 SBT-1 SBT-2 SBT-3 SBT-5SB-0.5 SB-1 SB-2 SB-3 SB-5 SB-10 SB-15 SB-20 SB-30S型傳感器: TSC-50 TSC-100 TSC-200 TSC-300 TSC-500 TSC-1000TSB-2 TSB-3 TSB-5 TSH-200 TSH-300 TSH-500 TSH-1T TSH-2T TSH-3T TSH-5T單點(diǎn)傳感器: IL-150 IL-250 IL-500 IL-1000 IL-2000MT1022-3 MT1022-5 MT1022-7 MT1022-10 MT1022-15 MT1022-20 MT1022-30MT1041-10 MT1041-15 MT1041-20 MT1041-30 MT1041-50 MT1041-75 MT1041-100MT1241-50 MT1241-100 MT1241-150 MT1241-200 MT1241-250MT1260-50 MT1260-75 MT1260-100 MT1260-150 MT1260-200 MT1260-250 MT1260-300 MT1260-500 MT1260-635 MT1260-750 SSH-50 SSH-100 SSH-200 SSH-300 SSH-500 SSH-1000ssp-1022-6 ssp-1022-10 ssp-1022-30 ssp-1241-30 ssp-1241-50 ssp-1241-100 ssp-1241-200 ssp-1241-300ssp-1260-150 ssp-1260-300 ssp-1260-500 ssp-IL-1000 ssp-IL-2000 橋式傳感器:SBD-10 SBD-20 SBD-25 SBD-30波紋管傳感器:MTB-5 MTB-10 MTB-20 MTB-50 MTB-75 MTB-100 MTB-200 MTB-300 MTB-5OO輪輻式稱重傳感器:SBF-2.25 SBF-4.5 SBF-11.25 SBF-22.5 SBF-45搖柱式傳感器:GD-15 GD-20 GD-30 GD-50 GD-100 GD-200 GD-250 GD-300 GD-400 GD-500PGD-2 PGD-5 PGD-10 PGD-20 PGD-30 PGD-50ZY-15 ZY-20 ZY-30 高溫傳感器:GD(G)-15 GD(G)-20 GD(G)- 30 GD(G)-50 GD(G)-100 GD(G)-200 GD(G)-250 稱重模塊: FW-0.3 FW-0.5 FW-1 FW-2 FW-3 FW-5 FW-10 FW-20 CW-0.3 CW-1 CW-2 CW-3 CW-5 CW-10 CW-15 CW-20 FWC-0.22 FWC-0.55 FWC-1.1 FWC-2.2 FWC-4.4 FWC-9 FWC-13.6 FWC-20 CWC-0.22 CWC-0.55 CWC-1.1 CWC-2.2 CWC-4.4 CWC-9 CWC-13.6 CWC-20 GW-15 GW-20 GW-30 GW-50 GW- 100 GW-200 GW-250 GW-300 GW-400 GW-500 GWA-15 GWA-20 GWA-30 GWA-50 GWA-100 GWA-200 GWA-250 GWA-300 GWA-400 GWA-500 UW-5 UW-10 UW-20 GW-50 UW-75 UW-100 UW-200 UW-300 UW-500 PGW-2 PGW-5 PGW-10 PGW-20 PGW-30 PGW-50 PGWA-2 PGWA-5 PGWA-10 PGWA-20 PGWA-30 PGWA-50 DGW-50 DGW-100 DGW-200 DGW-250 DGW-300 DGW-400 DGW-500 DGWA-50 DGWA-100 DGWA-200 DGWA-250 DGWA-300 DGWA-400 DGWA-500 電流型模擬輸出模塊 GW-15-AOC GW-20-AOC 技術(shù)支持:QQ: 2240595355
郵箱:hbenaid@163.com
| ||
產(chǎn)品簡介
WRN-240防爆熱電偶是一種溫度傳感器,在化學(xué)工業(yè)自控系統(tǒng)中應(yīng)用極廣,通過溫度傳感器,可將控制對象的溫度參數(shù)變成電信號,傳遞給顯示儀表、記錄和調(diào)節(jié)儀表,對系統(tǒng)實(shí)行檢測、調(diào)節(jié)和控制。在化工廠,生產(chǎn)現(xiàn)場常伴有各種易燃、易爆等化學(xué)氣體、蒸汽、碳?xì)浠衔锏,如果使用普通熱電偶非常不安全,極易引起環(huán)境氣體爆炸。因此,在這些場合必須使用隔爆或本安型熱電偶作為溫度傳感器。另外它還具有多種防爆形式,防爆性能好,壓簧式感溫元件,抗振性能好,機(jī)械強(qiáng)度高,耐壓性能好。
工作原理
隔爆或本安熱電阻與裝配式熱電阻的結(jié)構(gòu)、原理基本相同,所區(qū)別的是,隔爆或本安型產(chǎn)品接線盒(外 殼)在設(shè)計(jì)上采用防爆特殊結(jié)構(gòu),接線盒用高強(qiáng)度鋁合金壓鑄而成,并具有足夠的內(nèi)部空間、壁厚和機(jī)械強(qiáng)度,橡膠密封圈的熱穩(wěn)定性均符合國家防爆標(biāo)準(zhǔn)。所以,當(dāng)接線盒內(nèi)部的爆炸性混合氣體發(fā)生爆炸時,其 內(nèi)壓不會破壞接線盒,而由此產(chǎn)生的熱能不能向外擴(kuò)散、傳爆。
主要技術(shù)指標(biāo)
量程規(guī)格
| | | | |
| | | | |
| |
注:”t“為感溫元件實(shí)測溫度,
熱響應(yīng)時間
在溫度出現(xiàn)階躍變化時,熱電偶的輸出變化至相當(dāng)于該階躍變化的50%所需的時間,稱為熱響應(yīng)時間,用 T0.5表示。
公稱壓力
一般是指常溫下,保護(hù)管所能承受的靜態(tài)外壓而不破裂,試驗(yàn)壓力一般采用公稱壓力的1.5倍。實(shí)際上,允許工作壓力不僅與保護(hù)管材料、 直徑、壁厚有關(guān),而且還與其結(jié)構(gòu)形式、安裝方法、置入深度以及被測介質(zhì)的流速、種類有關(guān)。
熱電偶絕緣電阻
常溫絕緣電阻的試驗(yàn)電壓為:直流500±50V。
測量常溫絕緣電阻的大氣條件為:溫度15~35℃,相對濕度45%,大氣壓力86~106kPa。
對于長度>1米的熱電偶,常溫絕緣電阻值與其長度的乘積應(yīng)不小于 100 MΩ.M即:Rr·L>100 MΩ·m L>1m式中:Rr-熱電偶的常溫絕緣電阻值, MΩ;L-熱電偶的長度,m
對于長度≤1米的熱電偶,常溫絕緣電阻值應(yīng)不小于100 MΩ
防爆類型和級組
防爆級組:dⅡBT4或dⅡCT4 dⅡBT6或dⅡCT6
本安級組:iaⅡBT4或iaⅡCT4(多對式)
iaⅡBT6或iaⅡCT6(多對式)
外殼防護(hù)等級IP65
原理結(jié)構(gòu)
隔爆或本安熱電偶與裝配式熱電偶的結(jié)構(gòu)、原理基本相同,所區(qū)別的是,隔爆或本安型產(chǎn)品接線盒(外殼)在設(shè)計(jì)上采用防爆特殊結(jié)構(gòu),接線盒用高強(qiáng)度鋁合金壓鑄而成,并具有足夠的內(nèi)部空間是、壁厚和機(jī)械強(qiáng)度,橡膠密封圈的熱穩(wěn)定性均符合國家防爆標(biāo)準(zhǔn)。所以,當(dāng)接線盒內(nèi)部的爆炸性混合體氣體發(fā)生爆炸時,其內(nèi)壓不會破壞接線盒,而由此產(chǎn)生的熱能不能向外擴(kuò)散一傳爆。
由于產(chǎn)品采用上述防爆特殊結(jié)構(gòu),使產(chǎn)品完全符合使用在dⅡBT4至dⅡCT6、ibIIBT4、iaIIBT4、iaIICT6防爆類別范圍內(nèi),只要用戶遵守產(chǎn)品使用規(guī)則,產(chǎn)品就能達(dá)到可靠的防爆效果。
型號表示
| | | | ||||
| | | 鎳鉻硅-鎳鉻 | ||||
| 鎳鉻-鎳硅 | ||||||
| 鎳鉻-銅鎳 | ||||||
| 銅-銅鎳 | ||||||
| 鐵-銅鎳 | ||||||
| | 偶絲對數(shù) | |||||
| 單支 | ||||||
| 雙支 | ||||||
| | 安裝固定形式 | |||||
| 無固定裝置 | ||||||
| 固定螺紋 | ||||||
| 固定法蘭 | ||||||
| 活絡(luò)管接頭式 | ||||||
6 | 固定螺紋錐型管式 | ||||||
| | ||||||
| | ||||||
| | | |||||
| 16mm | ||||||
| 代號 | 工作端形式 | |||||
K | 鎧裝內(nèi)芯 |