<legend id="dnf07"></legend>
    • <tr id="dnf07"><dfn id="dnf07"></dfn></tr>

      <dl id="dnf07"><label id="dnf07"></label></dl>
    • AXIS-ULTRA型島津/KRATOS高性能成圖X射線光電子能譜儀

      并且,若在圖像上以鼠標(biāo)點(diǎn)擊指定分析位置,則無需移動(dòng)樣品,便可進(jìn)行最小至15mm微小區(qū)域的多點(diǎn)能譜分析!鷪D像分辨率(邊緣分辨率) 2mm左右→XPS靈敏度 宏 11,800kcps / 110mmf 735kcps 27mmf 28kcps / (Ag3d5/2、450W、1.3eV)→最小分析直徑(能譜分析) 15mmf

      聚焦型掃描X-射線熒光能譜儀

      技術(shù)參數(shù)1.微聚焦X光管最大功率40kV, 1.0mA2.試樣上X光聚焦點(diǎn)直徑300um,100um,40um3.10x黑白,100x(200x)彩色CCD攝像頭4.樣品室尺寸330x250x330mm5.自動(dòng)樣品臺行程100x100x100mm主要特點(diǎn)  1.樣品范圍寬:液體,磁性,絕緣體,少量粉末等。2.樣品尺寸大:塊狀樣品可達(dá)250x200x90mm。3.焦點(diǎn)小,可進(jìn)行點(diǎn)、線、面的分布分析。4.能量利用率高,X光管功率小,維護(hù)簡便。5.無損檢測,使用方便,自動(dòng)化程度高。 儀器介紹 EAGLE III聚焦型掃描X-射線熒光能譜儀也稱熒光探針,采用聚焦X射線照射,光路系統(tǒng)采用正置式,可在大氣壓力或低真空環(huán)境下檢測樣品。該儀器可進(jìn)行視頻圖象采集和圖象拼接,微區(qū)及整體成分的定性定量分析,以及線、面元素的分布分析,檢測極限為ppm級。  

      ATY-Q30低本底多道γ能譜儀

       

      ATY-Q30低本底多道γ能譜儀主要技術(shù)特點(diǎn):
       1、該儀器由中國測試研究院刻度和檢定(儀器都單獨(dú)出具“檢定證書”),確保儀器指標(biāo)完全符合國家質(zhì) 量監(jiān)督檢驗(yàn)檢疫總局2002年1月1日實(shí)施的“建筑材料放射性核素限量(GB6566-2001)”之檢驗(yàn)標(biāo)準(zhǔn)。符合γ譜
      ATY-Q30低本底多道γ能譜儀儀檢定規(guī)程(JJG 417-2006)
       2、測量精度:當(dāng)樣品的比活度大于18.5Bq/Kg時(shí),其總不確定度不大于15%;
      3、測量時(shí)間:室內(nèi)定量分析2550秒;現(xiàn)場快速分析:500秒;
       4、采用低功耗1024道多道脈沖分析器。儀器分辨率:優(yōu)于8%(137Cs 0.66MeV);積分非線性≤0.003%;微分非線性≤4%;死時(shí)間≤10微秒;
       5、單核素標(biāo)準(zhǔn)物質(zhì)進(jìn)行校準(zhǔn),快速、準(zhǔn)確、方便;
      6、在能區(qū)50keV-3000keV內(nèi)本底計(jì)數(shù)率不大于6s-1(cps);
      7、Windows全中文操作系統(tǒng),人機(jī)對話,漢字菜單顯示,操作簡單方便;
       8、整機(jī)功耗:電流小于300mA;
      9、使用溫度: 0℃—50℃。
      ATY-Q30低本底多道γ能譜儀配置
            1、  智能化低本底多道γ能譜儀1024道主機(jī)一臺;[符合γ譜儀檢定規(guī)程(JJG 417)]       2、  高靈敏低鉀NaI(Tl)能譜探頭一個(gè)(Ф75×75mm);[符合γ譜儀檢定規(guī)程(JJG 417)]       3、  新一代標(biāo)準(zhǔn)鉛室1套(壁厚100mm,內(nèi)徑200mm);[符合γ譜儀檢定規(guī)程(JJG 417)]       4、  標(biāo)準(zhǔn)物質(zhì)容器一套;       5、  系統(tǒng)操作軟件一套;       6、  通訊電纜一根;       7、  國家放射性標(biāo)準(zhǔn)物質(zhì)一套(鐳、釷、鉀各一份);       8、  國家放射性標(biāo)準(zhǔn)物質(zhì)證書3份(鐳、釷、鉀各一份);       9、  放射性標(biāo)準(zhǔn)樣品盒一套;       10、 國家級儀器鑒定證書一份(中國測試技術(shù)研究院);       11、 用戶使用說明書一份;       12、 品牌電腦一臺;       13、 打印機(jī)一臺(選配品);
      γ譜儀檢定規(guī)程(JJG 417)簡介:
           1、 [NaI(TI)]探測器       [NaI(TI)]探測器由 [NaI(TI)]晶體、光電倍增管和前置放大器組成,是 [NaI(TI)]γ譜儀的重要組成部分。測鐳-226、釷-232、鉀-40等天然放射性活度時(shí) [NaI(TI)]晶體尺寸應(yīng)不小于ф75mm×75mm。       2、 屏蔽室         屏蔽室是γ譜儀的重要組成配件。測量鐳-226、釷-232、鉀-40等天然放射性活度時(shí)屏蔽室壁厚不小于100mm鉛當(dāng)量,內(nèi)腔直徑不小于200mm。       3、 多道脈沖幅度分析器         應(yīng)有實(shí)時(shí)間和活時(shí)間功能,道數(shù)不小于512道。       4、 樣品盒         使用規(guī)格化的、有固定形狀和容量的、密封性好的圓柱形或凹形杯樣品盒。樣品盒應(yīng)選用天然放射性核素含量低的材料制成,如ABS塑料等。推薦使用標(biāo)準(zhǔn)化的ф76mm×70mm
      該公司產(chǎn)品分類: 其他 光電子科技產(chǎn)品 金屬探測器 勞保產(chǎn)品 工具 地質(zhì)儀器 其它 物位計(jì) 液位計(jì) 流量儀表 轉(zhuǎn)速表 內(nèi)窺鏡 檢測儀/校準(zhǔn)儀 汽車檢測及外圍產(chǎn)品 多功能測試儀 驗(yàn)電器 天平 鉗形表 示波器 電纜故障測試儀

      UCS30-PC伽瑪能譜儀

      UCS30-PC伽瑪能譜儀

       

       

      詳情介紹

       

       

      美國SPECTECH公司UCS30-PC伽瑪能譜儀為能譜實(shí)驗(yàn)設(shè)計(jì)的多選擇的操作系統(tǒng)。

       

      UCS30-PC 系統(tǒng)用于普通的電腦的能譜儀,可運(yùn)行在2000/XP系統(tǒng)下。外置單元通過USB接口接電腦,1024MCA和前置放大器,電腦控制放大器,高壓(0-2048V),上平和下平鑒別器和多道測量可做半衰和衰變的學(xué)習(xí)研究。也包括一個(gè)前置放大器輸出±12 V) 連接探測器用外置的前置放大器,相匹配的計(jì)數(shù)器和CdZnTe探頭。

      UCS30-PC伽瑪能譜儀完整的系統(tǒng)包括:NaITl)閃爍體探頭的鉛室和多階樣品架,8片放射性同位素源,MCA軟件有峰識別和實(shí)驗(yàn)說明書CD

                       

      UCS30 USB Computer Spectrometer

       

      Designed as a direct replacement for the popular model UCS20, the UCS30 nuclear spectrometer offers many enhancements and additional features for increased flexibility. USB connectivity provides plug and play operation with most of computers running Windows 2000 or XP. Three models are available with 1024, 2048 and 4096 channels of conversion gain.

      The internal preamplifier allows direct connection to scintillation detectors. The bipolar amplifier includes polarity selection and multiple shaping times when using different types of detectors with external preamplifiers. Upper and lower level discriminators may be set for rejection of unwanted signals. The high voltage supply is rated to +2048V for use with scintillation or proportional detectors. Optional polarity selection is available for use with detectors requiring negative bias. A preamplifier power connector (±12V) is included for use with our model PA-1 external preamplifier. A 10µsec fixed conversion ADC allows high throughput with deadtime correction. Input selection for preamplifier, amplifier or ADC direct is included by computer control.

      In addition to the normal pulse height analysis mode the UCS30 may be operated as a Multichannel Scaler for time correlated studies such as half-life decay. A special Mossbauer mode is included with MSB output for synchronization of the drive circuit. X-ray mapping may be performed with the optional ROI output.

      For ease of setup an auto-calibrate mode is provided that automatically sets the HV and amplifier gain to 1 keV/ channel using a Cs-137 source. Once the system is calibrated all parameters may be saved as setup files for quick recall of specific measurements. Data may be saved as binary files for reloading into memory or as spreadsheet compatible files for data processing.

      A background buffer is included for storing a spectrum when background subtraction, factional spectrum stripping or overlay is required. Multiple ROIs may be set with calculation of gross and net area. Presets include Real Time, Live Time and ROI Integral.

      Isomatch includes a text editable library of common isotopes. When loaded, markers are placed on the display at the positions of the isotope energies to aid in identification.

      Multiple UCS30s may be connected to a single computer providing USB ports are available. The internal power supply is UL, CE and CSA listed for operation worldwide. Warranty is one year parts and labor, return to factory.

      Specifications:Hardware.

      ·    Physical: Bench top enclosure with USB 2.0 interface includes preamplifier, amplifier, detector high voltage, up to 4096-channels depending on model, Multichannel Analyzer with data memory, LLD and ULD. Pulse height analysis and Multichannel Scaling modes. Fully compatible with many scintillation detectors and commercial tube bases.

      ·   Data Input: BNC connector multi-function input. On-board relays select internal preamplifier, shaping amplifier or direct to ADC when using external signal processing.

      ·     Gate Input: BNC connector. Normally open gate. TTL low closes gate to ADC.

      ·    HV Output: MHV connectors. Positive output, (switched positive or negative outputs with HV option). (SHV connectors optional), 0-2048 volts, 1mA maximum current at 1000 volts. High voltage is fully regulated and computer controlled in 2 volt increments.

      ·     MCS Input: BNC connector bypasses internal preamp/amplifier. Accepts positive TTL signal >150nsec., 5MHz maximum rate.

      ·    ROI Output: BNC connector. Generates pulse each time an event occurs in set region of interest. Requires ROI option.

      ·    MSB Output: BNC connector. TTL output of dwell counter most-significant-bit for synchronizing Mossbauer drive.

      ·    USB: USB type “A” connector. USB 2.0 standard.

      ·   Preamplifier: Charge sensitive preamplifier for use with scintillation detectors and PMTs.

      · Amplifier: Bipolar shaping amplifier with selectable peaking times of 1, 2, 4 and 8µsec. Computer controlled coarse and fine gain from x1 to x160. Input polarity selection.

      ·    External Preamp Power: DB-9F connector supplies ±12 volts.

      ·   ADC: Fixed conversion 10usec. Computer selected conversion gain from 256 to 4096 channels depending on model. Direct input accepts pulse peaking times of 0.5µsec. to 10µsec. Includes dead-time correction when used in Live-time mode.

      ·  LLD & ULD: Independently computer controlled discriminators over entire input range. Operates prior to ADC for reduced system dead time.

      ·   Modes: MCA for pulse height analysis, MCS for half-life decay or other time related studies and Mossbauer mode.

      ·   Timers: Real-time or Live-time operation selectable in 1-second increments for PHA, or dwell times from 10msec. to 60sec. per channel in MCS mode. In Mossbauer mode, 100usec. to 500usec.

      ·   Data Memory: On-board dynamic RAM, up to 4096 channels x 3 Bytes for data, plus region-of-interest flag.

      ·  Deadtime: System dead time is computed and displayed on screen during acquisition.

      ·  Power: AC line, 100-250VAC, 50/60Hz, auto-sensing internal power supply with Universal Power Cord input.

      Software.

      · System: Operates under Windows 2000/XP.

      · Display: Color or monochrome monitor, Vertical scale adjusts from 32 to 16M and LOG display. Horizontal 4096 channels depending on model with expansion down to 128 channels.

      · Time Mode: Preset live-time or preset real-time selection. Both times are recorded and displayed.

      · Count Mode: Preset count mode integral of  region-of-Interest.

      · ROIs: Multiple Regions-of Interest using color coding.

      · Integral: When cursor is in ROI, computes gross area, net area with end point averaging, centroid and FWHM.

      · Energy Cal: 2-point linear or 3-point quadratic converts cursor position reading directly to energy units. (Time units in MCS mode.)

      · Autocalibrate: Use with Cs-137 source to automatically calibrate system for 1 keV/channel.

      · Bkgd Buffer: Used to store background spectrum for time normalized background subtraction.

      · Subtract: Subtracts channel-by-channel time normalized data stored in Background Buffer from display data.

      · Smooth: 3-point smoothing of displayed data. Does not modify data in acquisition memory.

      · Control: Software control of Input Selector, High Voltage and Polarity (with HV option), Amplifier Input Polarity, Peaking Time, Gain, Lower and Upper level discriminators, and ADC Conversion Gain.

      · File: Save or load data file and header information in binary format or as CSV/TSV files. Save or load setup files for specific configurations.

      · Clipboard: Clips data and header information, graphic screens, ROI data containing, centroid, FWHM, gross and net integrals, and header information in spreadsheet compatible format for transferring into other applications.

      · ISOMATCH: Isotope library text file with peak markers and labeling for overlaying on spectrum. Provides quick isotope identification. Libraries may be edited and extended using word processors or text editor programs.

       

      Ordering Information.

       

      UCS301K Universal Computer Spectrometer 1024 channel for Windows 2000/XP

      UCS302K Universal Computer Spectrometer 2048 channel for Windows 2000/XP

      UCS304K Universal Computer Spectrometer 4096 channel for Windows 2000/XP

      UCS30-HV Positive or negative high voltage option

      UCS30-ROI Region of Interest pulse output option

       

      Accessories

      LS325 Environmental lead shield for 2" or 3" detectors.

      SD51 2x2 in. NaI(Tl) with integral photomultiplier.

      TS51-2 Tube base stand, 14-pin for 2" or 3" detectors, complete with cables.

      PA1 External preamplifier for proportional counters.

      SP78W-2 Well detector complete with stand, LS2000 lead shield and cables.

      SPA38 Complete detector assembly with 38x38mm detector, stand, LS038 shield and cables.

      Spectrum files can be transferred from the ICS 10 DOS program and the ICSW 16 Windows program to the UCS-30 Windows version.

      Most functions may be accessed by more than one method. All the functions can be accessed from the Pull Down Menu, some from the Tool Bar Buttons, or by the mouse. If the function has a Tool Bar Button, its symbol will be shown on the left hand side of the description.

       

       

      該公司產(chǎn)品分類: 核醫(yī)學(xué)常用儀器設(shè)備 紅外線放射率測試器遠(yuǎn)紅外測試儀 輻射環(huán)境檢測儀器 輻射防護(hù)設(shè)備 CT、X線機(jī)質(zhì)控檢測儀器設(shè)備

      FYFS-2002E全自動(dòng)低本底多道γ能譜儀

      FYFS-2002E全自動(dòng)低本底多道γ能譜儀

          ●每臺均由中南國家計(jì)量測試中心檢定。確保儀器指標(biāo)符合國家質(zhì)量技術(shù)監(jiān)督檢驗(yàn)檢疫總局發(fā)布實(shí)施的GB6566—2001《建筑材料放射性核素限量》、GB50325—2001《民用建筑工程室內(nèi)環(huán)境污染控制規(guī)范》、GB5101—2003《燒結(jié)普通磚》、GB13545—2003《燒結(jié)空心磚和空心砌塊》之標(biāo)準(zhǔn)。  ●工作環(huán)境溫度為0~40℃,工作環(huán)境濕度≤Rh90%,可分析核素能量范圍:30KeV—2MeV  ●能量分辨率:≤7.5%(137Cs)  ●系統(tǒng)能量線性:≤1%  ●樣品中鐳—226、釷—232、鉀—40放射性比活度之和大于37Bq/kg時(shí),本儀器的測量擴(kuò)展總不確定度≤12% (K=2)  ●系統(tǒng)穩(wěn)定性:≤1%  ●可分析道位:1024道  ●自動(dòng)處理后鉛室測量本底:≤240cpm  ●分析核素種類:鐳—226、釷—232、鉀—40(可根據(jù)用戶要求擴(kuò)充鈾—238、銫—137、鈷—60)

      型號:M296503 紫外能譜儀

      紫外能譜儀 型號:M296503  
      61M6100型紫外能譜儀可用于檢查各種光學(xué)儀器(設(shè)備)和光學(xué)文件波長的性,也可以測量其中各譜線的相對強(qiáng)弱。 適用于各級技術(shù)監(jiān)督部門以及儀器、元件生產(chǎn)單位。 主要技術(shù)參數(shù): 1 波長范圍: 190-875nm 2 單色器狹縫帶寬: 0.1 , 0.2 , 0.4 , 2.0nm 四檔 3 波長度: ± 0.3nm 4 波長掃描速度分三檔,慢檔: 10nm/min ;中檔: 30nm/min ;快檔: 60nm/min 5 波長校準(zhǔn)方式:汞燈校準(zhǔn)。經(jīng)校準(zhǔn)后,波長度可達(dá) ± 0.1nm  

      低本底多道伽瑪能譜儀

       
      低本底多道伽瑪能譜儀
      用途技術(shù)指標(biāo)】
      技術(shù)參數(shù):
      能量分辨率:(對137Cs)優(yōu)于8%。
      測量不確定度:(比活度>35Bq/kg)≤20%。
      多道分析器: 1024道;微分非線性:≤1.0%; 積分非線性:≤0.1%;時(shí)鐘頻率80MHz
      屏蔽室:鉛屏蔽厚度10cm,重約900kg。
      測量時(shí)間:1秒~(223-1)秒,即1秒~97天,動(dòng)態(tài)顯示測量進(jìn)程,中途暫信可繼續(xù)測量。
      全譜測量:全譜參加計(jì)算和數(shù)據(jù)處理充分利用有用信息,樣品分析快速和數(shù)據(jù)處理。
      系統(tǒng)穩(wěn)定性:≤±1%(8h)
      工作環(huán)境: 溫度5℃~35℃;相對濕度≤90%;
                 電源AC220v±10%。50Hz±1Hz。
      儀器用途:
      粉末樣品測量:檢測建筑材料粉末樣品中的放射性核素鐳(226Ra)、釷(232Th)、鉀(40K)的比活度,給出被測樣品的內(nèi)、外照射指數(shù)(Ira及Ir)。
      無損快速檢測:檢測規(guī)則建材中的放射性核素226Ra、232Th、40K的比活度及內(nèi)、外照射指數(shù)(Ira及Ir)。
      特點(diǎn):非破壞性測量,快速無損、節(jié)約測量成本,提高工作效率。
      活性炭盒法測量土壤中的氡濃度。
      儀器主要配置
      由線性放大器、數(shù)模變換器(ADC)及微機(jī)接口等組成的多道分析器專用卡。
      數(shù)據(jù)采集與處理軟件。
      譜分析軟件。
      無損測量軟件(選配)
      活性炭測氡軟件(選配)
      聯(lián)想專用計(jì)算機(jī)、打印機(jī)及17寸純平顯示器。
      粉末測量、無損測量及活性炭測量的公用多功能型鉛室。
      鐳、釷、鉀、標(biāo)準(zhǔn)源。
      符合GB6566-2001《建筑材料放射性核素限量》的國標(biāo)要求。
      該儀器可由“中國計(jì)量科學(xué)研究院”認(rèn)證,并出具檢定證書。
       

      XR-306X射線熒光能譜儀,熒光X-Rey射線鍍層測量儀

      SEA5100采用Si Li半導(dǎo)體檢測器,使之測量分辨率大大提高,彌補(bǔ)了用比例計(jì)數(shù)管檢測時(shí)有些元素難以區(qū)分的不足,配備有小型準(zhǔn)直器,不僅可以進(jìn)行元素分析,也可測量鍍層厚度,與薄膜FP法配合使用時(shí),可以不使用標(biāo)準(zhǔn)樣品,就可以進(jìn)行元素分析及鍍層測量。標(biāo)準(zhǔn)配備有Windows2000中文操作界面,采用檢量線法和FP法,測量數(shù)據(jù)與Word和Excel鏈接,自動(dòng)生成報(bào)告和數(shù)據(jù)處理,2個(gè)準(zhǔn)直器可自動(dòng)切換,工作臺3維電動(dòng),可編程進(jìn)行自動(dòng)測量
      利用微小的X射線束流來進(jìn)行微小的異物分析雖然從微小的異物得到的信號量不隨照射異物的X射線束流大小而改變,但是從底材得到信號隨著束流的減小而減小,相對來說,從異物得到的信號跟底材的比增強(qiáng)。于是,微小的X射線束流在進(jìn)行微小的異物和樣品時(shí),發(fā)揮著重要的作用。
      方便簡單的多點(diǎn)分析和成像利用多彩的掃描方法,自動(dòng)的測量樣品的表面,簡單明了的表示出2維或者3維的元素分布,膜厚組成分布等的成像。
      鮮明的樣品畫像和定性分析對比表示通過光亮的照明和倍率切換,可以得到擴(kuò)大90倍的畫像,可以清楚的觀察到微小的部分,通過鼠標(biāo)和操縱桿,可以自由自在的移動(dòng)樣品,利用標(biāo)有準(zhǔn)直器尺寸的十字線,來不斷的確認(rèn)和調(diào)整需要分析部分的位置。通過電鍍部分和材質(zhì)的能諳對比,確認(rèn)曲線重合部分的元素的同時(shí),正確的設(shè)定測量條件。
      自動(dòng)完成分析報(bào)告分析測量結(jié)束后,點(diǎn)擊輸出報(bào)告的按鍵,便自動(dòng)的啟動(dòng)報(bào)告編輯軟件。自動(dòng)的表示出測量條件,樣品圖像,能譜,X射線強(qiáng)度,分析數(shù)據(jù)等。以此為基礎(chǔ)進(jìn)行編輯,可以簡單的完成數(shù)據(jù)詳細(xì)、具有說服力的分析報(bào)告。

      STF-A低本底伽瑪能譜儀

      STF-A型低本底多道γ能譜儀是一種建材專用底本低多道γ能譜儀系統(tǒng),是為貫徹國家GB6566-2001《建筑材料放射性核素限量》、GB50325-2001(2006年版)《民用建筑工程室內(nèi)環(huán)境污染控制規(guī)范》、GB5101-2003《燒結(jié)普通磚》、GB13545-2003《燒結(jié)空心磚和空心砌塊》而改進(jìn)設(shè)計(jì)的一款譜儀,主要用于建材、土壤、生物、地質(zhì)樣品等γ能譜測量分析。     產(chǎn)品特點(diǎn)     譜儀硬件部分操作簡單、使用方便,軟件使用簡單方便。譜獲取仿真控制軟件可自動(dòng)測量,建材專用譜分析軟件使用時(shí)只需輸入樣品重量一個(gè)參數(shù),系統(tǒng)即可自動(dòng)計(jì)算出樣品中226Ra、232Th、40K的比活度(Bq/kg)及樣品的內(nèi)照射系數(shù)Ira 和外照射系數(shù)Iγ,并打印出核素分析報(bào)告,用戶可由此判斷建筑主體材料的使用范圍及裝修材料的裝修等級。

      主要技術(shù)指標(biāo)     1、系統(tǒng)能量分辨率:≤7.6%(Cs-137)     2、系統(tǒng)能量線性:≤±1%(59keV-2.0MeV)     3、分析核素種類:鐳-226、釷-232、鉀-40、銫-137(可根據(jù)用戶要求擴(kuò)充核素)     4、核素比活度分析誤差:分析誤差≤20%     5、系統(tǒng)穩(wěn)定性:≤±1%(8小時(shí))     6、鉛室本底計(jì)數(shù)率:≤5.6計(jì)數(shù)/秒

      XR-806X射線熒光能譜儀

          儀器配置  ²儀器核心部件采用美國Amptek公司生產(chǎn)的X-123系統(tǒng),集成了Si-PIN高分辨率半導(dǎo)體X射線探測器、高性能放大和整形電路、數(shù)字脈沖處理器以及脈沖高度分析器即MCA,http://www.qiantuo.netBrookfield 賽多利斯 防爆應(yīng)急燈 防爆泛光燈最大限度地發(fā)揮探測器的性能。  ²X射線管高壓發(fā)生器采用美國Spellman公司生產(chǎn)的50W高壓電源,性能指標(biāo),為儀器的運(yùn)行提供了保障! ²采用專業(yè)廠家生產(chǎn)的薄鈹窗X射線管,功率達(dá)50W,專業(yè)化封裝,輻射安全和各項(xiàng)性能指標(biāo)滿足應(yīng)用要求! ²配置多種經(jīng)過精心設(shè)計(jì)的濾光片,http://www.dgtairui.com 多功能血液溶漿機(jī) 精密增力電動(dòng)攪拌器 防爆無極燈 防爆投光燈使得XR-306型X射線熒光能譜儀不僅分析塑膠材料中的有害物質(zhì)時(shí)可以達(dá)到非常高的精度,同時(shí),分析金屬材料中的Pb和Cd等有害物質(zhì)也可以達(dá)到很好的精度! ²濾光片自動(dòng)轉(zhuǎn)換讓操作人員無需掌握深入的理論即可進(jìn)行的測量! ²推拉式開蓋方式結(jié)合開放式樣品腔設(shè)計(jì)地解決了超大樣品的檢測問題,做到小樣品測試安全方便,大樣品測試只要按系統(tǒng)提示操作同樣能操作人員安全。  ²精心設(shè)計(jì)的應(yīng)用程序不僅可以使用戶方便的檢測,http://www.gkzhan.com/st51852 栓劑模具 小型包衣機(jī) 西藥壓片機(jī) 安瓿熔封機(jī) 西林瓶輸液瓶軋蓋機(jī)還提供非常漂亮的檢測報(bào)告,對用戶開放報(bào)告格式定制功能,無論何種格式的報(bào)告都可以定制。此外還提供了數(shù)據(jù)輸出到Excel表格的功能,方便用戶進(jìn)行統(tǒng)計(jì)分析! ²高清晰度攝像頭的設(shè)置不僅使檢測報(bào)告圖文并茂,結(jié)合所配備的多孔經(jīng)準(zhǔn)直器還可以對不均勻樣品進(jìn)行定點(diǎn)檢測! Ø開放式的軟件設(shè)計(jì),出廠前已配置了常用材料的分析方法,用戶經(jīng)過培訓(xùn)以后也可以建立自己的分析方法,拓展儀器的使用范圍,如其他微量元素的分析和鍍層測厚。石油試驗(yàn)器 臭氧滅菌設(shè)備 干熱滅菌烘箱 流化床包衣機(jī) 塑料開煉機(jī) 雙輥機(jī) 黎明液壓濾芯 BlueM 腐蝕電解池 BOSCH電磁閥 純凈水生產(chǎn)線 糊盒膠 全自動(dòng)水質(zhì)采樣器 智能測汞儀 防腐型電磁流量計(jì) 壓力試驗(yàn)機(jī)廠家 裝載機(jī)電子秤 FESTO氣動(dòng)元件 污泥濃度計(jì) 氣動(dòng)薄膜調(diào)節(jié)閥 插床  洗地機(jī) 膠囊充填機(jī) 土肥儀 全自動(dòng)車床 大鼠ELISA試劑盒 BURKERT電磁閥 組織搗碎勻漿機(jī) 塑料萬能試驗(yàn)機(jī) IC卡電表價(jià)格 威化機(jī) 色譜填料 電化學(xué)金電極 捆草機(jī) 摩擦系數(shù)測試儀 熱熔裝訂機(jī)

        

      最新產(chǎn)品

      熱門儀器: 液相色譜儀 氣相色譜儀 原子熒光光譜儀 可見分光光度計(jì) 液質(zhì)聯(lián)用儀 壓力試驗(yàn)機(jī) 酸度計(jì)(PH計(jì)) 離心機(jī) 高速離心機(jī) 冷凍離心機(jī) 生物顯微鏡 金相顯微鏡 標(biāo)準(zhǔn)物質(zhì) 生物試劑
      亚洲阿v天堂在线观看2019,97免费人妻视在线视频,成人网站不卡在线观看,亚洲成av人电影在线无码
      <legend id="dnf07"></legend>
        • <tr id="dnf07"><dfn id="dnf07"></dfn></tr>

          <dl id="dnf07"><label id="dnf07"></label></dl>