技術(shù)參數(shù):德國凱馳Karcher(廣州博勵)全自動洗地機(jī)吸干機(jī) | |
洗地寬度 毫米 | 800 |
吸水寬度 毫米 | 990 |
凈/污水箱 升 | 120/120 |
洗地效率 平米/小時 | 3200 |
刷子轉(zhuǎn)速 轉(zhuǎn)/分 | 200 |
刷子觸地壓力(可調(diào)) | 36 克/平方厘米 |
電機(jī)功率 瓦 | 1660 |
重量 公斤 | 170 |
電線桿裂縫寬度測試儀主要技術(shù)參數(shù):
主機(jī)參數(shù)屏幕尺寸:5英寸 液晶分辨率:160×128 體積:195×140×45mm 重量:0.8kg主機(jī)外殼防水、防塵、防震測量范圍0.01 ~ 2.00mm讀數(shù)精度0.005mm放大倍數(shù)40倍最小分度0.02mm供電方式內(nèi)置鋰電池連接線長2.5m主機(jī)重量0.8kg工作環(huán)境溫度-10℃~40℃包裝規(guī)格材質(zhì):工程塑料體積:×315×170mm 重量:5kg
Rat Interleukin 10(IL-10)
ELISA Kit
Catalog No. CSB-E04595r
(96T)
l This immunoassay kit allows for the in vitro quantitative determination of rat IL-10 concentrations in serum, plasma and Tissue Homogenates.
l Expiration date six months from the date of manufacture
l FOR RESEARCH USE ONLY. NOT FOR USE IN DIAGNOSTIC PROCEDURES.
PRINCIPLE OF THE ASSAY
The microtiter plate provided in this kit has been pre-coated with an antibody specific to IL-10. Standards or samples are then added to the appropriate microtiter plate wells with a biotin-conjugated polyclonal antibody preparation specific for IL-10 and Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. Then a TMB (3,3',5,5' tetramethyl-benzidine) substrate solution is added to each well. Only those wells that contain IL-10, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of a sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450 nm ± 2 nm. The concentration of IL-10 in the samples is then determined by comparing the O.D. of the samples to the standard curve.
DETECTION RANGE
3.12 pg/ml-200 pg/ml. The standard curve concentrations used for the ELISA’s were 200 pg/ml, 100 pg/ml, 50 pg/ml, 25 pg/ml, 12.5 pg/ml, 6.25 pg/ml, 3.12 pg/ml.
SPECIFICITY
This assay recognizes rat IL-10. No significant cross-reactivity or interference was observed.
SENSITIVITY
The minimum detectable dose of rat IL-10 is typically less than 0.78 pg/ml.
The sensitivity of this assay, or Lower Limit of Detection (LLD) was defined as the lowest protein concentration that could be differentiated from zero.
MATERIALS PROVIDED
Reagent | Quantity |
Assay plate | 1 |
Standard | 2 |
Sample Diluent | 1 x 20 ml |
Biotin-antibody Diluent | 1 x 10 ml |
HRP-avidin Diluent | 1 x 10 ml |
Biotin-antibody | 1 x 120μl |
HRP-avidin | 1 x 120μl |
Wash Buffer | 1 x 20 ml (25×concentrate) |
TMB Substrate | 1 x 10 ml |
Stop Solution | 1 x 10 ml |
STORAGE
1. Unopened test kits should be stored at 2-8°C upon receipt and the microtiter plate should be kept in a sealed bag. The test kit may be used throughout the expiration date of the kit, provided it is stored as prescribed above. Refer to the package label for the expiration date.
2. Opened test plate should be stored at 2-8°C in the aluminum foil bag with desiccants to minimize exposure to damp air. The kits will remain stable until the expiring date shown, provided it is stored as prescribed above.
3. A microtiter plate reader with a bandwidth of 10 nm or less and an optical density range of 0-3 OD or greater at 450nm wavelength is acceptable for use in absorbance measurement.
REAGENT PREPARATION
Bring all reagents to room temperature before use.
1. Wash Buffer If crystals have formed in the concentrate, warm up to room temperature and mix gently until the crystals have completely dissolved. Dilute 20 ml of Wash Buffer Concentrate into deionized or distilled water to prepare 500 ml of Wash Buffer.
2. Standard Centrifuge the standard vial at 6000-10000rpm for 30s. Reconstitute the Standard with 1.0 ml of Sample Diluent. This reconstitution produces a stock solution of 200 pg/ml. Allow the standard to sit for a minimum of 15 minutes with gentle agitation prior to making serial dilutions. The undiluted standard serves as the high standard (200 pg/ml). The Sample Diluent serves as the zero standard (0 pg/ml). Prepare fresh for each assay. Use within 4 hours and discard after use.
3. Biotin-antibody Centrifuge the vial before opening. Dilute to the working concentration using Biotin-antibody Diluent(1:100), respectively.
4. HRP-avidin Centrifuge the vial before opening. Dilute to the working concentration using HRP-avidin Diluent(1:100), respectively.
Precaution: The Stop Solution provided with this kit is an acid solution. Wear eye, hand, face, and clothing protection when using this material.
OTHER SUPPLIES REQUIRED
Microplate reader capable of measuring absorbance at 450 nm, with the correction wavelength set at 540 nm or 570 nm.
Pipettes and pipette tips.
Deionized or distilled water.
Squirt bottle, manifold dispenser, or automated microplate washer.
An incubator which can provide stable incubation conditions up to 37°C±0.5°C.
SAMPLE COLLECTION AND STORAGE
l Serum Use a serum separator tube (SST) and allow samples to clot for 30 minutes before centrifugation for 15 minutes at 1000 g. Remove serum and assay immediately or aliquot and store samples at -20°C. Centrifuge the sample again after thawing before the assay. Avoid repeated freeze-thaw cycles.
l Plasma Collect plasma using citrate, EDTA, or heparin as an anticoagulant. Centrifuge for 15 minutes at 1000 g within 30 minutes of collection. Assay immediately or aliquot and store samples at -20°C. Centrifuge the sample again after thawing before the assay. Avoid repeated freeze-thaw cycles.
l Tissue Homogenates 100mg tissue was rinsed with 1X PBS, homogenized in 1 mL of 1X PBS and stored overnight at -20° C. After two freeze-thaw cycles were performed to break the cell membranes, the homogenates were centrifuged for 5 minutes at 5000 x g, 2 - 8°C. The supernate was assayed and removed immediately. Alternatively, aliquot and store samples at -20°C or -80℃. Centrifuge the sample again after thawing before the assay. Avoid repeated freeze-thaw cycles.
Note: Grossly hemolyzed samples are not suitable for use in this assay.
ASSAY PROCEDURE
Bring all reagents and samples to room temperature before use. It is recommended that all samples, standards, and controls be assayed in duplicate. All the reagents should be added directly to the liquid level in the well. The pipette should avoid contacting the inner wall of the well.
1. Add 100μl of Standard, Blank, or Sample per well. Cover with the adhesive strip. Incubate for 2 hours at 37°C.
2. Remove the liquid of each well, don’t wash.
3. Add 100μl of Biotin-antibody working solution to each well. Incubate for 1 hour at 37°C. Biotin-antibody working solution may appear cloudy. Warm up to room temperature and mix gently until solution appears uniform.
4. Aspirate each well and wash, repeating the process three times for a total of three washes. Wash: Fill each well with Wash Buffer (200μl) and let it stand for 2 minutes, then remove the liquid by flicking the plate over a sink. The remaining drops are removed by patting the plate on a paper towel. Complete removal of liquid at each step is essential to good performance.
5. Add 100μl of HRP-avidin working solution to each well. Cover the microtiter plate with a new adhesive strip. Incubate for 1 hour at 37°C.
6. Repeat the aspiration and wash five times as step 4.
7. Add 90μl of TMB Substrate to each well. Incubate for 10-30 minutes at 37°C. Keeping the plate away from drafts and other temperature fluctuations in the dark.
8. Add 50μl of Stop Solution to each well when the first four wells containing the highest concentration of standards develop obvious blue color. If color change does not appear uniform, gently tap the plate to ensure thorough mixing.
9. Determine the optical density of each well within 30 minutes, using a microplate reader set to 450 nm.
CALCULATION OF RESULTS
Using the professional soft "Curve Exert 1.3" to make a standard curve is recommended, which can be downloaded from our web.
Average the duplicate readings for each standard, control, and sample and subtract the average zero standard optical density. Create a standard curve by reducing the data using computer software capable of generating a four parameter logistic (4-PL) curve-fit. As an alternative, construct a standard curve by plotting the mean absorbance for each standard on the x-axis against the concentration on the y-axis and draw a best fit curve through the points on the graph. The data may be linearized by plotting the log of the IL-10 concentrations versus the log of the O.D. and the best fit line can be determined by regression analysis. This procedure will produce an adequate but less precise fit of the data. If samples have been diluted, the concentration read from the standard curve must be multiplied by the dilution factor.
LIMITATIONS OF THE PROCEDURE
The kit should not be used beyond the expiration date on the kit label.
Do not mix or substitute reagents with those from other lots or sources.
It is important that the Standard Diluent selected for the standard curve be consistent with the samples being assayed.
If samples generate values higher than the highest standard, dilute the samples with the appropriate Standard Diluent and repeat the assay.
Any variation in Standard Diluent, operator, pipetting technique, washing technique, incubation time or temperature, and kit age can cause variation in binding.
This assay is designed to eliminate interference by soluble receptors, binding proteins, and other factors present in biological samples. Until all factors have been tested in the Immunoassay, the possibility of interference cannot be excluded.
TECHNICAL HINTS
Centrifuge vials before opening to collect contents.
When mixing or reconstituting protein solutions, always avoid foaming.
To avoid cross-contamination, change pipette tips between additions of each standard level, between sample additions, and between reagent additions. Also, use separate reservoirs for each reagent.
When using an automated plate washer, adding a 30 second soak period following the addition of wash buffer, and/or rotating the plate 180 degrees between wash steps may improve assay precision.
To ensure accurate results, proper adhesion of plate sealers during incubation steps is necessary.
Substrate Solution should remain colorless or light blue until added to the plate. Keep Substrate Solution protected from light. Substrate Solution should change from colorless or light blue to gradations of blue.
Stop Solution should be added to the plate in the same order as the Substrate Solution. The color developed in the wells will turn from blue to yellow upon addition of the Stop Solution. Wells that are green in color indicate that the Stop Solution has not mixed thoroughly with the Substrate Solution.
上海東晟軸承,是高速發(fā)展的需要而誕生的專業(yè)化GAL50-UK-2RS軸承FAG銷售公司,長期經(jīng)銷世界各大知名品牌軸承進(jìn)口軸承型號查詢系統(tǒng)下載:瑞典SKF、德國FAGNSK軸承、INA、美國TIMKEN、日本NSK、NTN、IKO、KOYO、THK、NACHI進(jìn)口軸承。歡迎來電咨詢GAL50-UK-2RS軸承尺寸、價格、技術(shù)支持或同型號其他品牌替換等詳細(xì)資料!如果您對FAGGAL50-UK-2RS軸承有疑問,請聯(lián)系我們獲取更多GAL50-UK-2RS軸承的最新信息 FAG軸承。FAG供應(yīng)商供應(yīng)的產(chǎn)品主要應(yīng)用于FAG軸承地區(qū)的造紙、機(jī)械制造IKO日本、起重機(jī)器、汽車配套維修、工程機(jī)械、礦山機(jī)械、紡織機(jī)械聯(lián)系方式:電話 : 傳真: NADELLA伸縮導(dǎo)軌GAL50-UK-2RS軸承 GAL50-UK-2RS軸承價格 GAL50-UK-2RS軸承尺寸GAL50-UK-2RS軸承報價 GAL50-UK-2RS軸承圖片NADELLA軸承 【GAL50-UK-2RS軸承】尺寸參數(shù)表:軸承型號:GAL50-UK-2RS軸承品牌:FAG軸承系列:桿端軸承NADELLA伸縮導(dǎo)軌 上海東晟軸承有限公司提供FAG軸承GAL50-UK-2RS的鍛壓機(jī)床、回流焊接機(jī)、消聲室、銑齒機(jī)、消音降噪設(shè)備、等技術(shù)參數(shù)。公司以打造專業(yè)經(jīng)銷進(jìn)口軸承企業(yè)一流的服務(wù)為經(jīng)營理念,不斷為進(jìn)口軸承型號查詢系統(tǒng)下載NSK軸承用戶提供優(yōu)質(zhì)產(chǎn)品,不斷提升自我的技術(shù)服務(wù),使機(jī)械無憂運轉(zhuǎn)。使FAG軸承客戶在我們這得到滿意的服務(wù)和一流的產(chǎn)品。推薦型號:NACHI2311軸承 2310 NACHI 2307軸承 NACHI 2308 NACHI2306 NACHI2305軸承 2304 6905ZENR軸承 6005ZENR 6205ZENR軸承 6305ZENR 62/28ZENR軸承 63/28ZENR 6806ZENR軸承 6906ZENR 71922CD/DT 6220ZZ軸承 6013-RS1 6905V軸承 3216B.TVH UCT209軸承 TIMKEN軸承 德國NADELLA伸縮導(dǎo)軌 公司網(wǎng)站:http://www.bearings365.comhttp://www.zcsearch.comhttp://www.sh-bearings.comhttp://www.zhoucheng188.comhttp://www.ikont.com.cnhttp://www.shdszc.com參考資料:http://www.zhoucheng188.com/FAG/GAL50-UK-2RS.html
RJ518050旋轉(zhuǎn)關(guān)節(jié)產(chǎn)品特征:
Specifications | |||
Interface Type | 2.92 Female ( 50 ohms ) | Style | I Type |
Frequency Range | DC to 40 GHz | Phase WOW (Degrees Max.) | 1° |
VSWR, Max. | 1.30 @ DC to 10 GHz | Insertion Loss, ,Max. | 0.25 dB @ DC to 10 GHz |
1.45 @ 10 to 20 GHz | 0.40 dB @ 10 to 20 GHz | ||
1.60 @ 20 to 30 GHz | 0.55 dB @ 20 to 30 GHz | ||
1.75 @ 30 to 40 GHz | 0.70 dB @ 30 to 40 GHz | ||
VSWR WOW | 0.1 | Insertion Loss WOW | 0.02 dB |
Peak Power, Max. | 500 W | Average Power, Max. | 60 W @ 1 GHz |
Rotating Speed, Max. | 250 rpm | Life Time, Min. | 5 Million Revolutions |
Starting Torque | 3.5 Ncm. | Continuous Rotational Torque | 3.5 Ncm Max. |
Axial Load On Interface, Max | ± 1 N | Radial Load On Interface, Max. | ± 1 N |
Body Material | Stainless Steel | Contact Pin Material | Beryllium Copper |
DC Power Ability | 3 A * 24V @ Full RF Power | Contact Surface Finish | Gold Plate |
Weight | 0.014 kg | Marking | Adhesive Label |
Insulator Material | PTFE / Teflon | IP Protection Level | IP 64 Per EN 60529 |
Temperature(Ambient Range) | -40 to +60 °C (Operation) | Humidity | 85% (Operation) |
-50 to +70 °C (Storage) | (Non-Condensing), Max. | 95% (Storage) |
KEM自動滴定儀AT-710系列KEM自動滴定儀AT-710系列主要特點:AT-710M:觸摸屏和操作單元之間無線連接,同時控制四臺自動滴定測量單元。通過使用無線適配器(藍(lán)牙),操作單元和滴定裝置可以不用電纜連接。在測量樣品過程中有危害性氣體時,可將滴定裝置放置在排煙柜中,由無線傳輸?shù)牟僮鲉卧獔?zhí)行滴定。AT-710M/AT-710S:滴定劑的信息存儲在滴定管上的芯片中。即使滴定管單元轉(zhuǎn)移到另一個滴定裝置,也不需要重新輸入滴定劑信息。AT-710M/AT-710S/AT-710B:滴定管單元特殊的開關(guān)閥門。減少滴定管和開關(guān)閥門間的死體積。特殊結(jié)構(gòu)的設(shè)計可減少滴定劑的使用量和快速更換滴定單元。AT-710M/AT-710S/AT-710B:智能化電極電纜。電極的信息可透過電纜上傳感器存儲相關(guān)資料。電極校準(zhǔn)的數(shù)據(jù)可應(yīng)用到不同的自動滴定儀上。KEM自動滴定儀AT-710系列技術(shù)參數(shù):
名稱 | 自動電位滴定儀 | ||
儀器型號 | AT-710M | AT-710S | AT-710B |
儀器組成 | MCU-710M+AT-710+螺旋槳或磁力攪拌器 | MCU-710S+AT-710+螺旋槳或磁力攪拌器 | AT-710+螺旋槳或磁力攪拌器 |
測量范圍 | 1)電位: -2000.0~2000.0mV2) pH: -20.000~20.000pH3)溫度: 0~100°C | ||
滴定方式 | 自動滴定,自動間歇滴定,間歇滴定,恒pH滴定 | ||
石油中和值滴定,COD滴定 | |||
滴定類型 | 電位滴定(酸堿,氧化還原,沉淀),光度滴定,極化滴定,電導(dǎo)滴定 | ||
終點判斷 | 全量滴定(自動終點),自動終點滴定,設(shè)定終點滴定 | ||
交叉點滴定,自動終點/設(shè)定終點滴定 | |||
特殊應(yīng)用 | 量電極電位(pH, mV),酸解離常數(shù)(pKa) | ||
同時記錄雙通道電位,學(xué)習(xí)滴定 | |||
輸入設(shè)置 | 觸摸屏輸入 | 按鍵輸入 | |
顯示 | 1) 8.4英寸彩色液晶屏,800x600點 | 1) LED背景光源液晶屏 | |
2)英文/日文/中文/韓文/俄文/西語/德語/法語 | 2)英文/日文/中文/韓文/俄文/西語 | ||
3)四個通道同時顯示 | 3)一個通道顯示 | 3)一個通道顯示 | |
計算 | 濃度計算,統(tǒng)計計算(平均值,標(biāo)準(zhǔn)差,相對標(biāo)準(zhǔn)差),自動輸入空白和滴定度 | ||
數(shù)據(jù)儲存 | 500組樣品結(jié)果 | 50組樣品結(jié)果 | |
GLP認(rèn)證 | 登記操作者/使用群組管理滴定劑:提示滴定度測量日期/指示滴定劑剩余量/提示滴定管活塞更換日期/提示滴定劑換日期/滴定度測量履歷性能檢查:提醒計劃檢查日期/記錄檢查結(jié)果電極管理:記錄校正日期/記錄校正履歷/電極檢查/電極檢查履歷滴定管驗證:驗證/記錄驗證結(jié)果時間管理:顯示操作時間 | 登記操作者/記錄檢查結(jié)果/電極校正記錄/滴定管精度確認(rèn)/時間管理 | |
滴定管單元 | 20mL玻璃滴定管附褐色保護(hù)套(標(biāo)配),選配: 10mL,5mL或1mL | ||
滴定管精確度 | 50mL滴定管(自動注入器): ±0.5mL20mL滴定管: 0.02mL 重復(fù)性: 0.01mL10mL滴定管: 0.015mL 重復(fù)性: 0.005mL5mL滴定管: 0.01mL 重復(fù)性: 0.003mL1mL滴定管: 0.005mL 重復(fù)性: 0.001mL | ||
擴(kuò)大器 | 1) STD: pH(mV), mV,雙通道(標(biāo)配)2) PTA: pH(mV), mV,光度,三通道3) POA: pH(mV), mV,極化,三通道4) CMT: pH(mV), mV,電導(dǎo),三通道5) TET: pH(mV),pH(mv), mV,三通道 | ||
外部輸出 | RS-232C x3 | RS-232C x 2 | |
打印機(jī),電子天平,數(shù)據(jù)軟件(SOFT-CAP) | |||
USB x; 1 | USB x 1 | ||
U盤,熱敏打印機(jī),A4打印機(jī),鍵盤, 條碼機(jī),腳踏開關(guān), USB集線器 | U盤,熱敏打印機(jī),鍵盤,條碼機(jī),腳踏開關(guān), USB集線器,安卓設(shè)備 | ||
LAN x 1 :電腦(PC) | |||
擴(kuò)充功能 | 測量單元:電位滴定儀(AT-710)容量水分儀(MKV-710)庫侖水分儀MKC-710)最多四臺測量單元 | ||
自動活塞滴定管:最多可控制10臺滴定管驅(qū)動單元(包括主機(jī)兩臺) | |||
多樣品自動進(jìn)樣器: CHA-600,CHA-700 | CHA-700 | ||
使用環(huán)境 | 1)溫度: 5~35°C2)相對濕度: 85%RH以下 | ||
電源 | AC100~240V,50Hz/60Hz | ||
耗電量 | 主機(jī):約30瓦打印機(jī):約7瓦 | 主機(jī):約20瓦打印機(jī):約7瓦 | |
尺寸 | 觸摸屏: 225(W) x 190(D) x 42(H)mm | ||
滴定單元: 141(W) x 296(D) x 367(H)mm(不包括管路)打印機(jī): 106(W) x 180(D) x 88(H)mm | |||
重量 | 觸摸屏:約1.5公斤 | ||
滴定單元:約4.0公斤打印機(jī):約0.4公斤 |
BQS2KW排污排沙潛水泵
產(chǎn)品介紹 BQS(W)礦用隔爆型排污排沙潛水電泵,是泵和電動機(jī)組合一體的電力排灌設(shè)備,外型美觀,結(jié)構(gòu)簡單,密封性能好,性能穩(wěn)定,壽命長,安裝使用方便,且可以長期在水下連續(xù)作業(yè),被廣泛用于煤礦立井、斜井及井底散煤泥地自動化排水。內(nèi)裝式電泵,水由電動機(jī)夾層中流過,有效的延長了電泵的使用壽命;外裝式電泵,葉輪采用雙流道大過流結(jié)構(gòu),運行平穩(wěn),排污能力強(qiáng),防纏繞,無堵塞現(xiàn)象,并且有體積小,重量輕,攜帶方便的特點。結(jié)構(gòu)特點 BQS(W)系列的礦用隔爆型排污排沙潛水電泵嚴(yán)格根據(jù)煤炭行業(yè)標(biāo)準(zhǔn)MT/T671-2005《煤礦用隔爆型潛水電泵》、中華人名共和國國家執(zhí)行標(biāo)準(zhǔn)GB3836-2000《爆炸性氣體環(huán)境用電氣設(shè)備》設(shè)計制作,電動機(jī)采用Y型干式隔爆型三相異步電動機(jī),具有啟動轉(zhuǎn)矩大、運行性能好、噪聲低、體積小、重量輕、維護(hù)方便等特點,以及優(yōu)良的隔爆結(jié)構(gòu)性能和較高的防護(hù)等級,適用于含有甲烷或煤塵等爆炸性氣體環(huán)境、有爆炸危險的礦井下采掘面及巷道等場所與水泵配套使用。電泵采用O形橡膠密封圈作為靜密封,結(jié)構(gòu)性能好,采用橡膠硫化曲線控制技術(shù)保障了O型圈耐潮防老化的質(zhì)量及密封性能。動密封采用兩套機(jī)械密封,并有油室隔離保護(hù),有效地為轉(zhuǎn)動摩擦副提供潤滑,形成流體膜潤滑保護(hù),同時釋放在運動過程中積聚的熱量,從而延長了機(jī)械密封的使用壽命,確保了密封性能。電泵的流體部件材質(zhì)采用耐磨合金鑄鐵,水泵部分采用流體機(jī)械設(shè)計及平衡技術(shù),有效的延長了電泵的使用壽命。用途含有甲烷或煤塵爆炸危險的煤礦井下采掘工作面排水,煤礦立井、斜井施工排水,礦井無水倉井底主排水,主井井底散煤倉自動排水,老塘、無人區(qū)涌水自動排水,煤礦井下含有煤塵、泥沙等較小固體顆粒的地下水排放,清水倉排水,救災(zāi)搶險排水,城市環(huán)境系統(tǒng)中污水排放處理使用條件輸送介質(zhì)溫度應(yīng)不超過40℃,含固體顆粒的介質(zhì)、其體積濃度一般不超過2%,輸送介質(zhì)pH值在4~10范圍內(nèi),工作環(huán)境溫度0~40℃,水泵潛入水深值不超過5m,介質(zhì)中固體最大粒直徑不大于水泵流道過流斷面最小尺寸的50%基本參數(shù)
型號 | 流量 m3/h | 楊程 m | 功率 kW | 電壓 V | 電流 A | 額定 轉(zhuǎn)速 r/min | 電泵 效率 % | 通過顆粒最大直徑 mm |
15-15-2.2 | 15 | 15 | 2.2 | 380或660或1140 | 5.12或2.98 | 3000 | 33.3 | 10 |
25-10-2.2 | 25 | 10 | 34.5 |
手機(jī):18764769169 電話:
傳真: QQ:598298090
網(wǎng)站:http://www.jnzhuoxin.com
CKB型(B200型)單向楔塊超越離合器
CKB無內(nèi)環(huán)的單向楔塊型超越離合器基本參數(shù)和主要尺寸 長度單位:mm
安裝參考范例(Mounting e×ample)
IKA RCT磁力攪拌器產(chǎn)品優(yōu)勢新一代最為暢銷的實驗室儀器。New: 強(qiáng)力馬達(dá),轉(zhuǎn)速范圍廣New: 雙重溫度控制模式用于快速加熱介質(zhì)
IKA暢銷型RCT磁力攪拌器價格優(yōu)惠 - 內(nèi)置溫度控制系統(tǒng) - 隨機(jī)附送 PT 1000 溫度傳感器 (PT 1000.60) - 通過數(shù)顯屏可對加熱溫度和攪拌轉(zhuǎn)速進(jìn)行精確控制 - 數(shù)字顯示安全溫度設(shè)置 - 高溫警示>> ,提示用戶盤面高溫,小心燙傷 - 錯誤代碼數(shù)字顯示 - 加熱盤安全回路可調(diào) (5-360°C ) - 安全控制型加熱磁力攪拌器,適于無人操作 - DIN 12878 標(biāo)準(zhǔn)接口,可連接外部溫度及精確控溫,如:ETS-D5 - 先進(jìn)的熱控技術(shù),安全水平高 - 儀器密閉性好,保護(hù)等級高(IP 42),使用壽命長 - 磁性強(qiáng) - 隨機(jī)附送 H 100 保護(hù)膜 IKA暢銷型RCT磁力攪拌器價格優(yōu)惠 |
IKA RCT磁力攪拌器規(guī)格參數(shù)
加熱磁力攪拌器 | RCT 基本型(安全型) |
攪拌點位數(shù)目 | 1 |
每個攪拌點位最大攪拌量 (H2O) | 20 l |
單個攪拌點位的轉(zhuǎn)速偏差 | 5 % |
最大攪拌量 (H2O) | 20 l |
電機(jī)輸入功率 | 16 W |
電機(jī)輸出功率 | 9 W |
轉(zhuǎn)速顯示 | LED |
速度范圍 | 50 - 1500 rpm |
攪拌子最大長度 | 80 mm |
加熱輸出功率 | 600 W |
加熱速度 (1升 | H2O) | 6.5 K/min |
加熱溫度范圍 | 室溫 - 310 °C |
加熱溫度控制 | LED |
加熱溫度控制精確度 | 1 ±K |
轉(zhuǎn)速控制 | 無級 |
可調(diào)安全溫度回路最小值 | 50 °C |
可調(diào)安全溫度回路最大值 | 360 °C |
外接溫度傳感器接口 | 德國工業(yè)標(biāo)準(zhǔn)DIN 12 878 |
帶傳感器控溫精確度 | 1 ±K |
工作盤材質(zhì) | 鋁合金 |
工作盤外形尺寸 | Ø135 mm |
外形尺寸 | 160 x 85 x 270 mm |
重量 | 2.5 kg |
允許環(huán)境溫度 | 5 - 40 °C |
允許相對濕度 | 80 % |
DIN EN 60529 保護(hù)方式 | IP 42 |
電壓 | 220 - 230 / 115 / 100 V |
頻率 | 50/60 Hz |
儀器輸入功率 | 650 W |