EKGDH-24電動機(jī)保護(hù)器完善的電機(jī)智能監(jiān)控保護(hù)器是對電動機(jī)運(yùn)行過程中的各種運(yùn)行信息數(shù)據(jù)進(jìn)行采集、運(yùn)算、分析、監(jiān)控、報警、控制的綜合性裝置。裝置通過對故障報警,保護(hù)動作(保護(hù)脫扣)以及利用動作延時時間的設(shè)定來實現(xiàn)及時準(zhǔn)確的保護(hù),保生產(chǎn)的安全。電動機(jī)保護(hù)器,電動機(jī)監(jiān)控器還可以通過數(shù)據(jù)信息通訊,實現(xiàn)電動機(jī)運(yùn)行狀況的詳細(xì)信息在上位機(jī)上進(jìn)行實時監(jiān)測,并經(jīng)計算機(jī)數(shù)據(jù)處理提供管理信息。在設(shè)備可能產(chǎn)生重大故障前,越限報警可及時提醒管理人員進(jìn)行處理,避免了不必要的停機(jī)而對正常生產(chǎn)造成影響,最大限度地保證設(shè)備運(yùn)行和控制的有效性。當(dāng)電動機(jī)運(yùn)行參數(shù)達(dá)到預(yù)置的預(yù)警值時,保護(hù)裝置僅進(jìn)行預(yù)警,不觸發(fā)脫扣;但當(dāng)越限值達(dá)到預(yù)置的脫扣值時,保護(hù)裝置進(jìn)入脫扣觸發(fā)延時。在預(yù)置脫扣延時時間內(nèi)若設(shè)備恢復(fù)正常運(yùn)行,則取消脫扣執(zhí)行;而如果超過延時時限,則保護(hù)裝置發(fā)出脫扣信號,驅(qū)動執(zhí)行元件動作,斷開電源停止電動機(jī)運(yùn)行。在電動機(jī)控制裝置實現(xiàn)各項保護(hù)功能的同時,各種保護(hù)信息也由裝置生成并經(jīng)通信接口上送至計算機(jī)管理系統(tǒng)。
EKJDB
EKWDB
EKGDH-24
EKGDH-30
GDH-24
GDH-30
EKWPJ-A
EKWPJ-B
WPJ-A
WPJ-B
WDB-A
WDB-B
ZY202
MAM-A
MAM-B
WJB
WJB+50A
WJD-CS
WJB+1E
WJD-Y
YDBT-WY
KMB-Y
EKD2-A,B
DZB-A
DZB-B
DZJ-B
DZJ-A
DJB
DJB-YC-F
DJB-YC
ZY201
DJB-YE
KMA-Y
KMC-Y
DZJ-D
WJD
WJD-YD
EKGDH-24保護(hù)功能:
過載保護(hù)、斷相保護(hù)、三相不平衡保護(hù)、堵轉(zhuǎn)保護(hù)、漏電保護(hù)、接地故障保護(hù)、輕載保護(hù)、空載保護(hù)、短路保護(hù)。
控制功能:
直接起動、正反起動、星三角起動、直接旁路起動、自耦變壓器降壓起動、多方起動控制。
產(chǎn)品簡介: S200P(pci-ps2是一款pci轉(zhuǎn)ps2轉(zhuǎn)接卡. 支持兩路PS2輸入(鍵盤/鼠標(biāo)接口)和兩個USB輸入接口。 無須任何驅(qū)動程序和軟件,即插即用, |
[主要特點] 1、采用USB設(shè)計電路,計算機(jī)內(nèi)不用插卡,不受計算機(jī)型號的影響,任意配置; 2、內(nèi)置萬分之一的進(jìn)口電子天平,完成自動稱樣過程; 3、用連續(xù)自動送樣機(jī)構(gòu),一次可放置1~24個樣,自動完成稱樣、送樣、保存、打印結(jié)果;全過程無需人工干預(yù),大大減少人工的勞動強(qiáng)度和降低對人的熱輻射; 4、采用PID溫控技術(shù),硬件超溫保護(hù),控溫準(zhǔn)確,升溫快; 5、關(guān)鍵部件采用進(jìn)口原裝部件,提高儀器可靠性; 6、采用極為方便的干燥劑更換、電解液不回流、攪拌免調(diào)節(jié)設(shè)計,更易于測試和日常維護(hù); 7、采用獨特的數(shù)據(jù)采集電路和多極校正技術(shù),測試精密度和準(zhǔn)確度優(yōu)于GB/T214-1996標(biāo)準(zhǔn)的要求。 [技術(shù)參數(shù)] 測硫分辨率:0.01% 測硫范圍:0.1%~20% 測試時間:3~6min/個(依試樣種類和重量而定) 測試溫度:1150℃ 最高溫度:1200℃ 控溫精度:±5℃ 樣品數(shù)量:1~24個(可連續(xù)不斷的添加樣品) 試樣重量:約50mg 電源:220VAC±22VAC、50Hz±1Hz 相對溫度:RH≤80% 功率:<3.5KW
1 | 德國施邁賽SCHMERSAL限位開關(guān) | T4D064-21YR 1X90GR | 54 | 現(xiàn)貨特價 |
2 | 德國施邁賽SCHMERSAL磁開關(guān) | BN65-10Z/V | 4 | 現(xiàn)貨特價 |
3 | 德國施邁賽SCHMERSAL限位開關(guān) | Z4V7H332-11Y | 20 | 現(xiàn)貨特價 |
4 | 德國施邁賽SCHMERSAL限位開關(guān) | MV7H330-11Y | 30 | 現(xiàn)貨特價 |
5 | 德國施邁賽SCHMERSAL限位開關(guān) | M3V4D330-11Y | 20 | 現(xiàn)貨特價 |
6 | 德國施邁賽SCHMERSAL限位開關(guān) | T4D064-20/10Y | 20 | 現(xiàn)貨特價 |
7 | 德國施邁賽SCHMERSAL安全磁開關(guān) | BNS33-11Z | 29 | 現(xiàn)貨特價 |
8 | 德國施邁賽SCHMERSAL安全磁開關(guān) | BNS33-12Z | 10 | 現(xiàn)貨特價 |
9 | 德國施邁賽SCHMERSAL限位開關(guān) | T4D064-21Y | 12 | 現(xiàn)貨特價 |
10 | 德國施邁賽SCHMERSAL限位開關(guān) | TA064-12Y | 75 | 現(xiàn)貨特價 |
11 | 德國施邁賽SCHMERSAL限位開關(guān) | T4D064-10/20YR 2X90GR | 22 | 現(xiàn)貨特價 |
12 | 德國施邁賽SCHMERSAL限位開關(guān) | ML441-11Y-M20 | 10 | 現(xiàn)貨特價 |
13 | 德國施邁賽SCHMERSAL安全門開關(guān) | AZ17-11ZRK/B5 | 11 | 現(xiàn)貨特價 |
儀器介紹
JMP2000界面膨脹流變測定儀 儀器介紹 JMP2000型界面膨脹流變儀是我公司在從事多年專業(yè)精密測量儀器研發(fā)、生產(chǎn)技術(shù)的基礎(chǔ)上,與中科院理化研究所強(qiáng)強(qiáng)合作的成果,其核心技術(shù)已申請國家專利。它是一種新型的多功能的精密測量儀器,不僅保留了我公司生產(chǎn)的JM99系列動態(tài)膜壓記錄儀(膜天平langmuir film balance)的全部功能,而且提供了不同的壓縮速度、壓縮面積、壓縮方式(正弦、指數(shù)、馳豫等),以適應(yīng)在實際工作中不同用途的特殊需要,從而大大地拓展了應(yīng)用領(lǐng)域,是研究表面活性物質(zhì)表面特性必不可不少的測試手段。(例如在測定Gibbs彈性ε時,就需要滑障做正弦運(yùn)動) JMP2000型界面膨脹流變儀是基于langmuir槽法進(jìn)行界面膨脹粘彈性質(zhì)測量的專門儀器,可用于油/水或空氣/水界面膨脹粘彈性質(zhì)的測量,除保留了JM99系列動態(tài)膜壓記錄儀的勻速運(yùn)動方式以外,還可采用下列三種方式進(jìn)行工作:小幅低頻振蕩方式、宏觀形變穩(wěn)態(tài)方式、界面馳豫方式。其新用途還包括:可進(jìn)行界面膨脹模量(ε)、界面張力相位(Φ)、穩(wěn)態(tài)界面膨脹粘度(K)、界面膨脹粘度的實數(shù)部分(ε’)和虛數(shù)部分(ε”)的頻率譜以及界面基本馳豫過程的測量和研究。該儀器在應(yīng)用化學(xué)、生物膜、脂質(zhì)體、集成光學(xué)、非線性物理、光電學(xué)、稀釋活性源、LB膜、超分子構(gòu)型等領(lǐng)域都有廣泛的用途。 主要特點 1. 全部過程由PC計算機(jī)和前置單板機(jī)控制,具有非常好的可操作性和可重復(fù)性。 2. 主控程序是Win98、WinMe界面,操作簡便,圖像為標(biāo)準(zhǔn)BMP文件,可存儲打印,數(shù)據(jù)可二次處理。 3. 液槽表面積大,雙滑障。 4. 靈敏度高。 5. 噪聲小,振動小,走速平穩(wěn)。 6. 泄漏小。 技術(shù)指標(biāo) 1. 表面張力測量范圍:0毫牛/米~150毫牛/米(0mN/m~150mN/m) 2. 分辨率:< 0.05毫牛/米(0.05mN/m) 3. 檢測方式:吊片法(Wilhelmy Type) 4. 液槽類型:langmuir槽 5. 液槽體積:上層 70mm *150mm *8mm(W * L * H) 下層 60mm *150mm *8mm(W * L * H) 6. 最大測量面積:96.6cm2 7. 最小測量面積:19.32cm2 8. 滑尺:(LEAKPROOF)或(BARRIER)或自制中空滑障 9. 采樣周期:150秒~300秒(二級調(diào)速) 10. 電源電壓:AC220±10V 11. 電源頻率:50Hz 12. 最大消耗功率:<150W 13. 工作溫度:室溫 14. 工作濕度:30%~85%相對濕度 15. 正弦運(yùn)動方式:頻率0.001~1Hz,振幅1%~6%(相對于平衡面積) 16. 指數(shù)運(yùn)動方式:dlnA/dt為常數(shù),初始速度可調(diào),指數(shù)運(yùn)動時間在2000秒以上 17. 馳豫過程測量:瞬間(1~2秒)面積改變5%~30%
中文名【CN】 | 英文名【US】 | CAS 編號 | 規(guī)格【S】 | 報價【Price】 | 品牌【B】 | 貨號【N】 |
---|---|---|---|---|---|---|
XAD-2 大孔樹脂 | Amberlite® XAD2 | 9060-05-3 | 250G | 648.00 | SUPELCO | 3025-U |
XAD-2 大孔樹脂 | Amberlite® XAD2 | 9060-05-3 | 500G | 1,056.00 | SUPELCO | 3025-U |
XAD-2 大孔樹脂 | Amberlite® XAD2 | 9060-05-3 | 1KG | 1,935.00 | SUPELCO | 3025-U |
XAD-2 大孔樹脂 | Amberlite® XAD2 | 9060-05-3 | 5KG | 8,950.00 | SUPELCO | 3025-U |
XAD-2 大孔樹脂 | Amberlite® XAD2 | 9060-05-3 | 25KG | 43,500.00 | SUPELCO | 3025-U |
XAD-2 大孔樹脂 | Amberlite® XAD2 | 9060-05-3 | 100KG | 149,000.00 | SUPELCO | 3025-U |
matrix | styrene-divinylbenzene (macroreticular) |
particle size | 20-60 mesh |
pore size | ~0.65 mL/g pore volume |
90 Å mean pore size | |
surface area | ~300 m2/g |
density | 1.02 g/mL at 25 °C (true wet)(lit.) |
1.08 g/mL at 25 °C (skeletal)(lit.) |
General description
非離子型大網(wǎng)格樹脂,通過疏水性和極性相互作用來完成
我的聯(lián)系方式王寶杰
北京北實縱橫科技發(fā)展有限公司
電話 :
手機(jī):13910327216
Q Q :
詳細(xì)介紹:
MODEL | 7470 | 7472 | 7473 | 7474 |
---|---|---|---|---|
Output Rating | 10KVAC/20mA | 12KVDC/10mA | 20KVAC/10mA | 20KVDC/5mA |
AC WITHSTAND VOLTAGE (7470&7473) | ||||
Range | Resolution | Accuracy | ||
Output Voltage, ACV (for 7473) | 0 - 20000 | 10 | ±(2% of setting + 20V) | |
Output Voltage, ACV (for 7470) | 0 - 10000 | 10 | ±(2% of setting + 10V) | |
Output Frequency | 50Hz/60Hz ±100ppm, User Selection | |||
Output Waveform | Sine Wave ,THD.<2% (Resistive Load), Crest Factor = 1.3 - 1.5 | |||
Output Regulation | ± (1% of output + 10V), From no load to full load | |||
SETTINGS | ||||
Hi / Lo -Limit AC Current, mA (for 7473) | 0 - 9.999 | 0.001 | ±(2% of setting + 2counts) | |
Hi / Lo -Limit AC Current, mA (for 7470) | 0 - 9.999/10.00 - 20.00 | 0.001/0.01 | ±(2% of setting + 2counts) | |
Ramp Up Time, second | 0.3 - 999.9 | 0.1 | ±(0.1% + 0.05sec) | |
Ramp Down Time, second | 0.0 - 999.9 | 0.1 | ||
Dwell Time | 0, 0.3 - 999.9 sec (0=continuous) | 0.1 | ||
0, 0.1 - 999.9 min (0=continuous) | 0.1 | |||
0, 0.1 - 999.9 hr (0=continuous) | 0.1 | |||
Cycle Test | 0 - 9999 Times, (0=continuous) | |||
Arc Detection | Range 1 - 7 > 15kV , Range 1 - 9 < 15kV | |||
AC Current Offset, mA | 0 - 2.000 or Auto Set ( Option ) | |||
MEASUREMENT | ||||
AC Voltage, KV (for 7473) | 0 - 20.00 | 0.01 | ±(2% of reading + 2counts) | |
AC Voltage, KV (for 7470) | 0 - 10.00 | 0.01 | ±(2% of reading + 2counts) | |
AC Current Range, mA | 0-3.500 | 0.001 | ±(2% of reading + 3counts) | |
3.00-10.00 (for 7473) | 0.01 | |||
3.00-20.00 (for 7470) | 0.01 | |||
DC WITHSTAND VOLTAGE (7472&7474) | ||||
Output Voltage, DCV (for 7474) | 0 - 20000 | 10 | ±(2% of setting + 20V) | |
Output Voltage, DCV (for 7472) | 0 - 12000 | 10 | ±(2% of setting + 10V) | |
Output Ripple | < 5%(在20KV/5000µA for 7474, 12KV/9999µA at Resistive Load for 7472) | |||
SETTINGS | ||||
Hi / Lo -Limit DC Current, µA (for 7474) | 0.0 - 999.9/1000 - 5000 | 0.1/1 | ±(2% of setting + 2counts) | |
Hi / Lo -Limit DC Current, µA (for 7472) | 0.0 - 999.9/1000 - 9999 | 0.1/1 | ±(2% of setting + 2counts) | |
Ramp Up Time, second | 0.4 - 999.9 | 0.1 | ±(0.1% + 0.05sec) | |
Ramp Down Time, second | 0.0,1.0 - 999.9 | 0.1 | ||
Dwell Time | 0, 0.4 - 999.9 sec (0=continuous) | 0.1 | ||
0, 0.1 - 999.9 min (0=continuous) | 0.1 | |||
0, 0.1 - 999.9 hr (0=continuous) | 0.1 | |||
Cycle Test | 0 - 9999 Times, (0=continuous) | |||
Arc Detection | Range 1 - 9 (9 is the most sensitivity) | |||
DC Current Offset, µA | 0.0 - 200.0 or Auto Set (Option ) | |||
Ramp High Current | ON/OFF, User Selection | |||
Charge - Low Current, µA | 0.0 - 350.0 or Auto Set | |||
Discharge Time | < 200 msec | |||
Maximum Capacitive Load | 1.5µF < 2KV 0.15µF < 8KV 0.12µF < 14KV 0.08µF < 20KV | |||
0.28µF < 4KV 0.15µF < 10KV 0.1µF < 16KV | ||||
0.18µF < 6KV 0.12µF < 12KV 0.08µF < 18KV | ||||
MEASUREMENT | ||||
DC Voltage, KV (for 7474) | 0 - 20.00 | 0.01 | ±(1.5% of reading + 2count) | |
DC Voltage, KV (for 7472) | 0 - 10.00 | 0.01 | ±(1.5% of reading + 2count) | |
DC Current Range, µA | 0-350.0 | 0.1 | ± (2% of reading + 3counts) | |
300-3500 | 1 | |||
3000 - 5000 (for 7474) 3000-9999 (for 7472) | 10 | |||
GENERAL | ||||
Input Voltage AC | 115/230VAC ± 15% , 50/60Hz ± 5% Fuse: 6.3A Slow | |||
PLC Remote Control | Input : Test , Reset , Memory1.2.3 ,Interlock | |||
Output : Pass , Fail , Processing | ||||
Safety | Smart-GFI Function (<1mA) | |||
Memory | 50 memories | |||
Display | 20*2 LCD with back light | |||
Key Lock | To prevent unauthorized alteration of the test Parameters | |||
Calibration | Build-in software and external calibrated meters | |||
Interface | RS232/GPIB /Printer Card (Option) | |||
Alarm Volume Setting | 10 ranges set by the numeric keys on the front panel | |||
Environment | 0-40℃, 20-80%RH | |||
Dimension | 430mm(W)×133mm(H)×400mm(D) | |||
Net Weight | 24Kg | 24Kg | 22.5Kg | 23Kg |
STANDARD ACCESSORIES | ||||
Power Cord (10A) | ×1 | |||
Fuses | ×2 (Including a spare contained in the fuse holder) | |||
Interlock Disable Key (1505) | ×1 | |||
Hipot Test Lead ,1.5m (1142) | - | - | ×1 | ×1 |
Hipot Test Lead ,1.5m (1143) | ×1 | ×1 | - | - |
Hipot Return Lead ,1.8m (1144) | ×1 | ×1 | ×1 | ×1 |
產(chǎn)品名稱:人白介素2可溶性受體α鏈(IL-2sRα/CD25)elisa試劑盒
產(chǎn)品編號:ARB10487
英文名稱:Human soluble interleukin-2 receptor,IL-2sRα ELISA kit
產(chǎn)品規(guī)格:96T/48T(盒裝)
產(chǎn)品貨期:2-3天
試劑盒保存:2℃-8℃,6個月
本試劑盒僅供科研使用,不得用于臨床診斷。
樣品采集:收集標(biāo)本前必須清楚要檢測的成份是否足夠穩(wěn)定。對收集后當(dāng)天進(jìn)行檢測的標(biāo)本,儲存在4℃?zhèn)溆?如有特殊原因需要周期收集標(biāo)本,將標(biāo)本及時分裝后放在-20℃或-70℃條件下保存。避免反復(fù)凍融。標(biāo)本2-8℃可保存48小時,-20℃可保存1個月。-70度可保存6個月。部分激素類標(biāo)本需添加抑肽酶。
結(jié)果計算:以標(biāo)準(zhǔn)物的濃度為橫坐標(biāo),OD值為縱坐標(biāo),在坐標(biāo)紙上繪出標(biāo)準(zhǔn)曲線,根據(jù)樣品的OD值由標(biāo)準(zhǔn)曲線查出相應(yīng)的濃度;再乘以稀釋倍數(shù);或用標(biāo)準(zhǔn)物的濃度與OD值計算出標(biāo)準(zhǔn)曲線的直線回歸方程式,將樣品的OD值代入方程式,計算出樣品濃度,再乘以稀釋倍數(shù),即為樣品的實際濃度。
我公司的生產(chǎn)的人白介素2可溶性受體α鏈(IL-2sRα/CD25)ELISA試劑盒性能穩(wěn)定可靠、靈敏度高、特異性強(qiáng),您可以放心購買,如有任何質(zhì)量問題,請與我們的售后服務(wù)聯(lián)系!
ELISA實驗應(yīng)注意的事項:
1.正式試驗時,應(yīng)分別以陽性對照與陰性對照控制試驗條件,待檢樣品應(yīng)作一式二份,以保證實驗結(jié)果的準(zhǔn)確性。
2.在ELISA中,進(jìn)行各項實驗條件的選擇是很重要的,其中包括:
(1)固相載體的選擇:目前常用的是40孔聚苯乙烯凹孔板。不管何種載體,在使用前均可進(jìn)行篩選:用等量抗原包被,在同一實驗條件下進(jìn)行反應(yīng),觀察其顯色反應(yīng)是否均一性,據(jù)此判明其吸附性能是否良好。
(2)包被抗體(或抗原)的選擇:將抗體(或抗原)吸附在固相載體表面時,要求純度要好,吸附時一般要求PH在9.0~9.6之間。吸附溫度,時間及其蛋白量也有一定影響,一般多采用4℃ 18~24小時。
(3)酶標(biāo)記抗體工作濃度的選擇:首先用直接ELISA法進(jìn)行初步效價的滴定。然后再固定其它條件或采取“方陣法”在正式實驗系統(tǒng)里準(zhǔn)確地滴定其工作濃度。
(4)酶的底物及供氫體的選擇:對供氫體的選擇要求是價廉、安全、有明顯地顯色反應(yīng),而本身無色。有些供氫體有潛在的致癌作用,應(yīng)注意防護(hù)。底物作用一段時間后,應(yīng)加入強(qiáng)酸或強(qiáng)堿以終止反應(yīng)。通常底物作用時間,以10-30分鐘為宜。底物使用液必須新鮮配制,尤其是H2O2在臨用前加入。
人白介素2可溶性受體α鏈(IL-2sRα/CD25)ELISA試劑盒相關(guān)的其他優(yōu)勢產(chǎn)品:
Aminex 糖分析柱的使用壽命長,并能保持上百次試驗的可重復(fù)性。耐用的層析柱避免了頻繁更換柱引起的數(shù)據(jù)變化和高成本。由聚苯乙烯二乙烯苯樹脂填裝而成的 Aminex HPLC 柱,具有良好的高壓及pH 穩(wěn)定性、高柱效和選擇性。Aminex HPLC 柱通過離子調(diào)節(jié)分配層析技術(shù)分離混合物,這種技術(shù)是根據(jù)多種不同的化學(xué)特性分離分子。離子調(diào)節(jié)分配層析技術(shù)的分離機(jī)制包括離子排阻、離子 交換、正相和反相分配、分子量排阻和配體交換。 根據(jù)層析的物理和化學(xué)特性,可選擇使用一個或多個分離機(jī)制。Aminex糖分析柱是工業(yè)界普遍使用的,用來分析碳水化合物、有機(jī)酸、有機(jī)堿和其它包括肽和核酸的有機(jī)小分子的標(biāo)準(zhǔn)產(chǎn)品。用Aminex 柱分離復(fù)雜混合物需要使用簡單等流相(常用水),并要求精確控溫。
研究過程中,樣品可重復(fù)的保留量和分辨率是至關(guān)重要的。不同批次間及不同柱間的測試證明Aminex 柱是值得信賴的產(chǎn)品。
Aminex糖分析柱的使用壽命長,并能保持上百次試驗的可重復(fù)性。耐用的層析柱避免了頻繁更換柱引起的數(shù)據(jù)變化和高成本。