手持式塵埃粒子計(jì)數(shù)器 便攜式塵埃粒子計(jì)數(shù)器 手持式粒子計(jì)數(shù)儀空氣粒子計(jì)數(shù)器 CJ-HLC 200A 手持式塵埃粒子計(jì)數(shù)儀 粒子計(jì)數(shù)儀 手持式激光粒子計(jì)數(shù)器
手持式塵埃粒子計(jì)數(shù)器簡(jiǎn)介
CJ-HLC200A手持式塵埃粒子計(jì)數(shù)器是用于測(cè)量潔凈環(huán)境中單位體積內(nèi)塵埃粒子數(shù)量和粒徑分布的儀器。手持式塵埃粒子計(jì)數(shù)器基本原理是光學(xué)傳感器的探測(cè)激光經(jīng)塵埃粒子散射后被光敏元件接收并產(chǎn)生脈沖信號(hào),該脈沖信號(hào)被輸出并放大,然后進(jìn)行數(shù)字信號(hào)處理,手持式塵埃粒子計(jì)數(shù)器通過與標(biāo)準(zhǔn)粒子信號(hào)進(jìn)行比較,將對(duì)比結(jié)果用不同的參數(shù)表示出來(lái)。儀器的測(cè)量參數(shù)設(shè)定、測(cè)量結(jié)果顯示、按鍵、定時(shí)、打印、時(shí)間、日期、數(shù)據(jù)存儲(chǔ)等均由內(nèi)置微機(jī)(MCU)控制和實(shí)現(xiàn),手持式塵埃粒子計(jì)數(shù)器可同時(shí)顯示環(huán)境的溫濕度并監(jiān)測(cè)報(bào)告激光粒子傳感器的工作狀態(tài)。該手持式塵埃粒子計(jì)數(shù)器按照國(guó)際通用標(biāo)準(zhǔn)設(shè)計(jì)(空氣采樣流量為2.83 升/分), 能同時(shí)對(duì)設(shè)定的兩個(gè)粒徑檔進(jìn)行檢測(cè),采樣時(shí)間可根據(jù)用戶需要任意設(shè)定,最長(zhǎng)時(shí)間59分59秒。手持式塵埃粒子計(jì)數(shù)器采樣數(shù)據(jù)可儲(chǔ)存在內(nèi)置的閃存內(nèi),該手持式塵埃粒子計(jì)數(shù)器在引進(jìn)美國(guó)的技術(shù)上進(jìn)一步創(chuàng)新, 具有測(cè)量精度高, 性能穩(wěn)定, 功能強(qiáng), 體積小, 操作簡(jiǎn)單方便, 達(dá)到或超過了國(guó)際同類產(chǎn)品的性能指標(biāo)。
手持式塵埃粒子計(jì)數(shù)器特性
• 200A型固定粒徑為:0.3μm ,可調(diào)粒徑為:0.5μm,0.7μm,1.0μm,2.0μm,3.0μm,5.0μm ,10.0μm;
測(cè)試范圍:10級(jí)~30萬(wàn)級(jí)(對(duì)應(yīng)ISO的4到9級(jí));
• 重復(fù)性:相對(duì)標(biāo)準(zhǔn)偏差≤20%;
• 粒徑度:相對(duì)誤差≤35%;
• 光源:采用激光二極管作為傳感器的光源;
• 流量:2.83 升/分(0.1cfm)(誤差≤±5%);
• 最大采樣時(shí)間:59分59秒;
• 接口:串口(外置打印機(jī)接口);
• 自凈時(shí)間:≤20min ;
• 計(jì)數(shù)超限報(bào)警:10級(jí)~30萬(wàn)級(jí)(對(duì)應(yīng)ISO的4到9級(jí));
• 手持式塵埃粒子計(jì)數(shù)器計(jì)數(shù)模式:累積計(jì)數(shù)模式、差分計(jì)數(shù)模式、濃度計(jì)數(shù)模式;
• 顯示:液晶128×64, 4行×8個(gè)(中文);
• 數(shù)據(jù)存儲(chǔ):最大存儲(chǔ)量為999組數(shù)據(jù);
• 手持式塵埃粒子計(jì)數(shù)器電源:Ni-MH電池(6.0V/3300mAH)或AC適配器(輸入:180~240V,輸出:9V/1000mA);
• 電池工作時(shí)間:連續(xù)測(cè)試時(shí)間約為8小時(shí)(Ni-MH電池);
• 外形尺寸:95(W)×180(H)×65(D)mm ;
• 手持式塵埃粒子計(jì)數(shù)器重量:約950g(含電池);
• 工作環(huán)境溫度:5~40℃相對(duì)濕度:≤75%;
• 標(biāo)準(zhǔn)附件:AC適配器、自凈過濾器、等動(dòng)力采樣頭、手提箱;
• 手持式塵埃粒子計(jì)數(shù)器選件:三角架、打印機(jī)(含電纜)、外置溫濕度傳感器;
執(zhí)行標(biāo)準(zhǔn):
美國(guó)ASTM F649-01標(biāo)準(zhǔn):“Standard Practice for Secondary Calibration of Airborne Particle Counter Using Comparison Procedures”
美國(guó) ASTM F328-98 標(biāo)準(zhǔn):“Standard Practice for Calibration of an Airborne Particle Counter Using Monodisperse Spherical Particles”
手持式塵埃粒子計(jì)數(shù)器功能:
• 日期和時(shí)間顯示
• COM內(nèi)置串行打印機(jī)接口:接串口打印機(jī)
• 計(jì)數(shù)超限報(bào)警:儀器可設(shè)置4級(jí)(十級(jí))、5級(jí)(百級(jí))、6級(jí)(千級(jí))、7級(jí)(萬(wàn)級(jí))、8級(jí)(十萬(wàn)級(jí))、9級(jí)(百級(jí))六個(gè)級(jí)別的計(jì)數(shù)超限報(bào)警
• 數(shù)據(jù)存儲(chǔ)器,可存950組測(cè)量結(jié)果
• 全中文界面,操作簡(jiǎn)單
• 外置傳感器能測(cè)量溫度、濕度并記錄存儲(chǔ)
手持式塵埃粒子計(jì)數(shù)器Brief Introduction
Airborne Particle Counter is an instrument used for the counting of particle amount and size distribution in clear environment. The main principle of the instrument is: after detecting laser of the laser sensor passed particles, the dispersed detecting laser is received by an optical sensitive component which will generate a pulse signal. The pulse signal is transmitted out and magnified. A conclusion can be made after the comparison between this signal and the pulse signal of standard particles. Through the MCU in the instrument, you can set parameters, print or store the results and time. The instrument can also report the humidity and temperature of the environment, as well as the working status of the laser sensor in the instrument. The design of the instrument follows the international standard (average Flow Rate of air sample is 2.83lpm). It can detect six kinds of particle size at the same time. Sample time can be set according to your request. The maximal sample time is 59min59sec. Sample data can be stored in built-in flash memory and transmitted out through a USB interface. The design of our Airborne Particle Counter is an innovation on American technology. The instrument has the features of high-accuracy, steady performance, strong function, small size, and being easy-to-use. Such features reached or surpassed that of other similar products in the international market
手持式塵埃粒子計(jì)數(shù)器Main Parameter
• Test particle size: fixed: 0.5μm;
• optional :0.3μm 、0.7μm、1.0μm、2.0μm、3.0μm 、5.0μm、10.0μm
• Test range: 10grade -0.3million grade
• Repeatability: relative standard deviation≤±10%
• Particle size accuracy: relative error≤±10%
• Light source: laser diode as the light source of the sensor
• Flow Rate: 2.83 l/min (0.1cfm) (error≤±5%)
• Maximal sample time: 59min59sec
• Self-purification time ≤10min
• Display: LCD128x64 pixels, 4line x 8 Chinese characters
• Interface: serial port (connect to external printer)
• Power supply: Ni-MH battery (6.0V/3300mAH)
• Battery working span: Successive testing time is approximately 8 hours (Ni-MH battery)
• Size: 95mm (W) × 180mm (H) × 65mm (D)
• Weight: 950g (with battery)
• Operating temperature: 5~45℃ ; Relative humidity ≤90%
• Storage temperature: -20~50℃ ; Relative humidity ≤90%
• Supplied accessories: AC adaptor, self-purifier, equal dynamic sampling probe, and suitcase
• Optional accessories: three-legged support, printer (with cable), or external temperature/humidity sensor
手持式塵埃粒子計(jì)數(shù)器Main functions:
1. Date and time display
2. COM internal serial printer interface: to connect with a printer
3. Over count alarm: six grades of over count alarm can be set up including 10grade, 100grade, 1000grade, 10000grade, 100000grade, 300000grade.
4. Data storage: 950 unites of data
5. External sensor for temperature & humidity measurement and data storage
6. Time-delay operation
7. Specially designed background light
Automatic power-off