產(chǎn)品展示 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
多氣體檢測(cè)儀MX6,復(fù)合氣體檢測(cè)儀,多氣體報(bào)警器MX6,六合一氣體檢測(cè)儀可同時(shí)檢測(cè)1到6種氣體,多氣體檢測(cè)儀MX6 iBridTM不僅僅是英思科最尖端監(jiān)測(cè)技術(shù)的智能產(chǎn)品,它也是世界第一款擁有彩色液晶顯示屏和任意選擇多種傳感器的復(fù)合式氣體監(jiān)測(cè)儀。 超大屏彩色顯示使得儀器可以在低亮,高亮等任何亮度環(huán)境下都很清晰地讀數(shù),增強(qiáng)了安全性。無(wú)論在室外,室內(nèi)或者地下的工作環(huán)境中,都能更容易發(fā)現(xiàn)潛在的氣體危害。 英思科氣體檢測(cè)儀MX6 iBridTM大存儲(chǔ)量的數(shù)據(jù)記錄和下載功能為用戶提供全面的 數(shù)據(jù)瀏覽和處理功能。 多氣體檢測(cè)儀MX6 iBridTM殼體堅(jiān)固,享受終身質(zhì)保,對(duì)于DS2臺(tái)和iNetTM儀器網(wǎng)絡(luò)完全兼容。 MX6美國(guó)英思科彩屏一氧化碳(CO)復(fù)合氣體檢測(cè)儀 多氣體檢測(cè)儀MX6主要技術(shù)參數(shù):外殼:不銹鋼、ABS、外部橡皮尺寸:135 mm × 77 mm × 43 mm (5.3" × 3.05" × 1.7")重量:409 克顯示和讀數(shù):彩色圖形LCD傳感器:可燃?xì)怏w,甲烷:催化燃燒 / 紅外法有毒氣體:電化學(xué)法二氧化碳: 紅外法VOCs:PID法溫度范圍:-20℃ to 55℃濕度范圍:15% to 95%電源和使用時(shí)間:可充電鋰電池約24小時(shí)可充電堿性電池(AA)約10.5小時(shí),連續(xù)工作10小時(shí),充電過(guò)程中仍可工作.認(rèn)證:本安: EEx ia d IIC T4Equipment Group and Category: II 2GClass I, Groups A,B,C,D T4; AEx ia d IIC T4Class I, Groups A,B,C,D T4 CFR30, Part 18 and 22, 本安對(duì)甲烷和空氣的混合氣體多氣體檢測(cè)儀MX6隨機(jī)提供:通用充電器 尼龍攜帶包 皮帶夾 標(biāo)定杯 腕帶 維修工具 說(shuō)明書 校準(zhǔn)軟管 過(guò)濾器、防水裝置(泵吸式)校準(zhǔn)裝置(泵吸式) 采樣軟管(泵吸式)歡迎您來(lái)電咨詢!
接口尺寸: | M12*1(mm) | 加工定制: | 是 |
防護(hù)等級(jí): | IP65 | 測(cè)量范圍: | 0-6to 0-600bar(kPa) |
類型: | 陶瓷型壓力變送器 | 防爆等級(jí): | 無(wú) |
型號(hào): | O-10(T) O-10(5) | 測(cè)量介質(zhì): | 液體 氣體 |
精度等級(jí): | 0.5 | 品牌: | WIKA/威卡 |
輸出信號(hào): | 4-20(mA) | 電源電壓: | 10-30(V) |
WIKA O-10(T) O-10(5)
通用型壓力變送器 用于液壓氣壓泵壓縮機(jī)
OEM pressure transmitter for general industrial applicationsModels O-10 (T), O-10 (5)
Pressure transmitter model O-10 (T)
Applications Hydraulics and pneumatics Pumps and compressors Machine building Building services
Special features Measuring ranges from 0 … 6 to 0 … 600 bar Non-linearity 0.5 % Standard industrial signals Electrical connection: Angular connector form A and C, circular connector M12 x 1, Metri-Pack series 150, cable outlet 2 m unshielded or shielded Many internationally customary process connections
Description
The model O-10 pressure transmitter has been developed for a wide variety of industrial applications. The large range of process and electrical connections as well as all commonly used pressure ranges and output signals set the model O-10apart.
For applications in which water is used as a medium we recommend a 5-fold overpressure safety in combination with a condensation-tight case.
Due to its specifications, its features and its price, the pressure transmitter is ideally suited to OEM applications, with an annual quantity requirement of more than 1,000 units of each article number. Accordingly, the minimum order quantity is 50 units per article number.
The model O-10 has been designed specifically for the demands of the global market. The pressure transmitter offers international units and the corresponding approvals for the North American and Russian markets.
It goes without saying that the model O-10 can be delivered with customer-specific labelling (e.g. company logo and model designation).
Versions
Model O-10 (T) Standard version
Model O-10 (5) With 5-fold overpressure limit and condensation-tight case
For applications with water as a medium we recommend a 5-fold overpressure safety for protection against water hammer effects, and a condensation-tight case.
Measuring ranges
Model O-10 (T)
Output signals
Model O-10 (T)
Voltage supply
Power supply The power supply depends on the selected output signal. 4 ... 20 mA: DC 8 ... 30 V DC 0.5 ... 4.5 V: DC 8 ... 30 V DC 0 ... 5 V: DC 8 ... 30 V DC 1 ... 5 V: DC 8 ... 30 V DC 0 ... 10 V: DC 14 ... 30 V DC 0.5 ... 4.5 V (ratiometric): DC 4.5 ... 5 V
The power supply for the pressure transmitter must be made via an energy-limited electrical circuit in accordance with section 9.4 of UL/EN/IEC 61010-1, or an LPS to UL/EN/IEC 60950-1, or class 2 in accordance with UL1310/UL1585 (NEC or CEC). The power supply must be suitable for operation above 2,000 m should the pressure transmitter be used at this altitude.
Total current consumption Current output: The total current consumption corresponds to the value of the output signal current (4 ... 20 mA), maximum 25 mA
Voltage output: 5 mA
Reference conditions (per IEC 61298-1)
Temperature 15 ... 25 °C
Atmospheric pressure 860 ... 1,060 mbar
Humidity 45 ... 75 % relative
Power supply Current output: DC 14 V Voltage output: DC 24 V Ratiometric output signal: DC 5 V
Nominal position Calibrated in vertical mounting position with pressure connection facing downwards.
Time response
Settling time < 2 ms
Accuracy data
Model O-10 (T)
Non-linearity (per IEC 61298-2) ≤ ±0.5 % of span BFSL A different non-linearity applies to some measuring ranges, see "Measuring ranges O-10 (T)".
Measuring deviation of the zero signal ≤ ±0.5 % of span
A different measuring deviation applies to some measuring ranges, see "Measuring ranges model O-10 (T)".
Accuracy at reference conditions ≤ ±1.2 % of span
Temperature error at 0 ... 80 °C ≤ ±1.5 % of span
Long-term stability ≤ ±0.3 % of span/year
Model O-10 (5)
Non-linearity (per IEC 61298-2) ≤ ±0.5 % of span BFSL
Measuring deviation of the zero signal ≤ ±1 % of span
Accuracy at reference conditions ≤ ±2.0 % of span
Temperature error at 0 ... 80 °C Mean temperature coefficient of zero point: Typical: 0.3 % of span/10 K Maximum: 0.6 % of span/10 K
Mean temperature coefficient of span: ≤ ±0.1 % of span/10 K
Long-term drift ≤ ±0.8 % of span/year
Operating conditions
Model O-10 (T)
Ingress protection (per IEC 60529) For ingress protections see "Electrical connections model O-10 (T)" The stated ingress protection only applies when plugged in using mating connectors that have the appropriate ingress protection.
Vibration resistance (per IEC 60068-2-6) 20 g (20 ... 2,000 Hz, 120 min.)
Shock resistance (per IEC 60068-2-27) 40 g (6 ms), mechanical shock
Service life 10 million load cycles
Free fall test Resistant to an impact onto concrete from 1 m
Permissible temperatures Medium: -30 ... +100 °C Ambient: -30 ... +100 °C Storage: -30 ... +100 °C
Model O-10 (5)
Ingress protection (per IEC 60529) For ingress protections see "Electrical connections model O-10 (5)" The stated ingress protection only applies when plugged in using mating connectors that have the appropriate ingress protection.
Vibration resistance (per IEC 60068-2-6) 20 g (20 ... 2,000 Hz, 120 min)
Shock resistance (per IEC 60068-2-27) 40 g (6 ms), mechanical shock
Service life 10 million load cycles
Free fall test Resistant to an impact onto concrete from 1 m
Permissible temperatures Medium: -40 ... +100 °C Ambient: -25 ... +80 °C Storage: -25 ... +80 °C
Other temperature ranges on request
Process connections
Materials
Non-wetted parts Stainless steel 316L PBT GF 30 Cable material (cable outlet) PVC
Wetted parts Stainless steel 316L 13-8 PH For sealing materials see "Process connections" Oil and grease free versions are available on request.
Electrical connections
Model O-10 (T) Available connections
Connection diagrams
Complete instrument
CE conformity
Pressure equipment directive 97/23/EC
EMC directive 2004/108/EC, EN 61326 emission (group 1, class B) and immunity (industrial application)
RoHS conformity Yes
Approvals cULus, safety (e.g. electr. safety, overpressure, ...), USA, Canada GOST-R, import certificate, Russia
Approvals see website
Accessories and spare parts Mating connector
Only use the accessories and spare parts listed above, otherwise it could lead to the loss of theapproval.
Ordering information Model / Measuring range / Output signal / Process connection / Electrical connection
歡迎致電咨詢訂購(gòu)WIKA O-10(T) O-10(5) 通用型壓力變送器 用于液壓氣壓泵壓縮機(jī)
電話: 56291930 15910733293
傳真:
QQ:823377546 1491421115 2636968574
郵箱:sales@zoriver.cn
公司官網(wǎng):http://www.zoriver.cn http://www.zoriver.com.cn
產(chǎn)品用途:我公司生產(chǎn)的HD系列恒流泵吸取國(guó)外技術(shù),利用空氣擠壓原理將液體吸出,并采用步進(jìn)電機(jī)作為動(dòng)力原使加液速度恒定?蛇m用多種規(guī)格的硅膠管,功率強(qiáng)、流量壓力可調(diào)、加液速度可無(wú)級(jí)調(diào)速。輸送物質(zhì)不與外界接觸,可防止污染,性能,是定量加液恒流加液器更新?lián)Q代的新產(chǎn)品。因此在各廠礦企業(yè)、大專院校、醫(yī)院及科研單位的生產(chǎn)和實(shí)驗(yàn)中得到廣泛使用,成為必備的不可缺少的儀器設(shè)備之一。凡需要輸液或抽液的場(chǎng)合均可使用。 | |||
◆ 產(chǎn)品特點(diǎn): | |||
◆ 技術(shù)指標(biāo):1. 流量: 2×5200ml/h(雙通道)2. 適用軟管:¢1×3mm ¢3×5mm ¢4×7mm3. 調(diào)速:無(wú)級(jí)調(diào)速4. 最大壓力:≤2kg5. 電源:220V±10% 50HZ6. 使用環(huán)境:溫度0-40℃; 濕度<85% |
型號(hào) | SHB-III/IIIA/IIIS/IIIT/IIIG |
功率(W) | 180 |
電源(V/Hz) | 220/50 |
流量(L/min) | 80 |
揚(yáng)程(m) | 10 |
最大真空度(MPa) | 0.098 |
單頭抽氣量(L/min) | 10 |
抽氣頭數(shù)(個(gè)) | 2 |
安全功能 | 逆流防止閥 |
水箱容積(L) | 15 |
水箱材質(zhì) | PP |
外形尺寸(mm) | 385L×280W×420H |
重量(kg) | 11 |
序號(hào) | 常見(jiàn)故障 | 查找部位 | 排除方法 |
1 | 真空表無(wú)真空顯示或真空指示不準(zhǔn) | 1.電機(jī)轉(zhuǎn)速不夠、電壓過(guò)低 | 檢查電壓是否穩(wěn)定 |
2.真空瓶、止回閥臟物堵塞或腐蝕 | 清理內(nèi)部臟物或更換新瓶、新閥芯 | ||
3.進(jìn)水口、濾管網(wǎng)堵塞 | 清晰,掏出內(nèi)部臟物 | ||
4.葉輪脫落 | 更換葉輪 | ||
5.真空表進(jìn)水或漏氣 | 甩出表內(nèi)存水,使表針回零或更換新表 | ||
6.真空管路堵塞或管龜裂 | 清洗管路貨更換新管 | ||
2 | 電機(jī)不工作 | 1.保險(xiǎn)管燒斷 | 更換新保險(xiǎn)管 |
2.運(yùn)轉(zhuǎn)電容被擊穿 | 更換與原來(lái)容量電壓相等的新電容 | ||
3.電機(jī)繞組燒壞 | 更換新電機(jī) | ||
4.軸承磨損嚴(yán)重卡死 | 更換新軸承 | ||
5.葉輪被堵卡死 | 清理雜物,校正葉輪位置 | ||
6.線頭虛焊或線卡松動(dòng) | 焊接牢靠,線卡卡緊 | ||
3 | 電機(jī)發(fā)熱、噪音過(guò)大 | 1.軸承磨損 | 更換新軸承 |
2.葉輪磨損變形 | 更換新葉輪 | ||
3.電壓不穩(wěn)或電壓過(guò)低 | 查線路是否過(guò)載和有無(wú)低電壓現(xiàn)象 | ||
4 | 水箱內(nèi)水花翻騰 | 1.濾水管排水方向不正確 | 調(diào)整排水方向 |
2.水位太低 | 加水到溢水口 | ||
5 | 漏水 | 1.水箱放溢水咀松動(dòng)或密封圈老化 | 擰緊水咀或更換密封圈 |
2.水箱破裂 | 更換水箱 |
技術(shù)參數(shù):
* 溫度范圍: -20~30℃;
* 控溫精度: ±0.1℃;
* 制 冷 量: 20℃時(shí)600W;
* 水箱容積: 8L;
* 循環(huán)泵最大壓力: 0.8Bar;
* 循環(huán)泵最大流量: 15L/min;
* 儀器接口尺寸: 3/8〞NPT
* 液槽尺寸: Φ250×D200mm
* 儀器外形尺寸: W300×D400×H720mm
* 儀器重量: 38KG
主要特點(diǎn):
* 立式設(shè)計(jì),占地面積小,操作方便;
* 液槽開(kāi)口大,便于在槽內(nèi)進(jìn)行實(shí)驗(yàn);
* 全封閉風(fēng)冷式壓縮機(jī)制冷,自帶延時(shí),過(guò)熱,過(guò)電流保護(hù);
* 可選擇不同的低溫設(shè)定值,自動(dòng)精密恒溫;
* 動(dòng)態(tài)控溫系統(tǒng),溫度波動(dòng)小,槽內(nèi)溫度均勻;
* 溫度顯示值和設(shè)定值,雙窗口雙色顯示,清晰直觀;
* 具有軟件鎖功能,無(wú)關(guān)人員不能隨便修改控制參數(shù);
* 標(biāo)準(zhǔn)不銹鋼接口,可配多種規(guī)格尺寸的接頭和軟管,外接閉路循環(huán);
* 超靜音循環(huán)泵,冷卻其它需要低溫的設(shè)備;
* 多種尺寸不銹鋼低溫槽,滿足各種低溫應(yīng)用;
* 前板可打開(kāi),便于清潔散熱器;
產(chǎn)品型號(hào)及技術(shù)參數(shù): 型號(hào):NFH10-P2MC-CF 最大流量:0~6L/H 型號(hào):NFH20-P2MC-CF 最大流量:0~12L/H ◆NIKKISO EIKO結(jié)合電子與定量加藥機(jī)之技術(shù),研發(fā)泛用型的電磁式加藥機(jī),液體接觸部以之耐腐蝕材質(zhì)為標(biāo)準(zhǔn),外型精致,體積小,易安裝NFH系列高精度,率,寬帶泛用電壓,適用地區(qū)廣。 產(chǎn)品特性: 1、防護(hù)等級(jí)IP65阻隔粉塵及水柱噴濺 2、寬帶電源AC單相100--240V,50HZ/60HZ共享 3、每分鐘沖程200SPM,流量調(diào)整范圍寬廣 4、數(shù)字表示,清楚易懂,操作容易 5、過(guò)熱保護(hù)裝置,溫度異常自動(dòng)跳機(jī),維護(hù)生命財(cái)產(chǎn)安全 產(chǎn)品用途: 水處理藥品加藥; 自動(dòng)化設(shè)備之藥液自動(dòng)添加 鍋爐防蝕防垢劑等加藥 游泳池、浴池殺菌劑加藥 食品相關(guān)之殺菌劑、色素、添加劑加藥
主要用途:
1. ISG立式單級(jí)管道離心泵,供輸送清水及物理化學(xué)性質(zhì)類似于清水的其他液體之用,適用于工業(yè)和城市給排水、高層建筑增壓送水、園林噴灌、消防增壓、遠(yuǎn)距離輸送、暖通制冷循環(huán)、浴室等冷暖水循環(huán)增壓及設(shè)備配套,使用溫度T<80℃! 2. IRG型立式熱水泵適用于冶金、化工、紡織、木材加工、造紙以及飯店、浴室、賓館等鍋爐高溫?zé)崴鰤貉h(huán)輸送以及城市住房采暖循環(huán)用泵,使用溫度120℃以下! 3. GRG型立式高溫離心泵廣泛用于:能源、冶金、化工、紡織、造紙以及飯店、浴室、賓館等鍋爐高溫?zé)崴鰤貉h(huán)輸送以及城市住房采暖循環(huán)用泵,使用溫度240℃以下! 4. IHG型立式不銹鋼管道離心泵,供輸送不含固體顆粒,具有腐蝕性,粘度類似于水的液體,適用于石油、化工、冶金、電力、造紙、食品制藥和合成纖維等部門,使用溫度為-20℃ ~ 120℃! 5. YG型管道油泵,供輸送汽油、煤油、柴油等石油產(chǎn)品,被輸送介質(zhì)溫度為-20℃ ~ + 120℃! 6. IHGB型立式不銹鋼防爆型化工離心泵,適用于輸送易燃性化工液體。 7. ISGD、IRGD、GRGD、IHGH、YGD、IHGBD型立式低速離心泵,適用于環(huán)境噪聲要求很低的場(chǎng)合及空調(diào)循環(huán)等。三、特點(diǎn): 1. 泵為立式結(jié)構(gòu),進(jìn)出口口徑相同,且位于同一中心線上,可象閥門一樣安裝于管路之中,外形緊湊美觀,占地面積小,建筑投入低,如加上防護(hù)罩則可置于戶外使用! 2. 葉輪直接安裝在電機(jī)的長(zhǎng)軸上,軸向尺寸短,結(jié)構(gòu)緊湊,泵與電機(jī)軸承配置合理,能有效地平衡泵運(yùn)轉(zhuǎn)產(chǎn)生的徑向和軸向負(fù)荷,從而保證了泵的運(yùn)行平穩(wěn),振動(dòng)小、噪音低! 3. 軸封采用機(jī)械密封或機(jī)械密封組合,采用進(jìn)口鈦合金密封環(huán)、中型耐高溫機(jī)械密封和采用硬質(zhì)合金材料,耐磨密封,能有效地延長(zhǎng)機(jī)械密封的使用壽命! 4. 安裝檢修方便,無(wú)需拆動(dòng)管路系統(tǒng),只要卸下泵聯(lián)體座螺母即可抽出全部轉(zhuǎn)子部件! 5. 可根據(jù)使用要求即流量和揚(yáng)程的需要采用泵的串、并聯(lián)運(yùn)用方式! 6. 可根據(jù)管路布置的要求采用泵的豎式和橫式安裝。四、工作條件: 1. 吸入壓力≤1.0MPa,或泵系統(tǒng)最高工作壓力≤1.6MPa,即吸入口壓力+泵揚(yáng)程≤1.6MPa、泵靜壓試驗(yàn)壓力為≤2.5MPa,訂貨時(shí)請(qǐng)注明系統(tǒng)工作壓力。泵系統(tǒng)工作壓力大于1.6MPa時(shí)應(yīng)在訂貨時(shí)另行提出,以便在制造時(shí)泵的過(guò)流部分和聯(lián)接部分采用鑄鋼材料! 2. 環(huán)境溫度<40℃,相對(duì)濕度<40%! 4. 所輸送介質(zhì)中固體顆粒體積含量不超過(guò)單位體積的0.1,粒度<0.2mm! 注:如果用介質(zhì)為帶有細(xì)小顆粒,請(qǐng)?jiān)谟嗀洉r(shí)說(shuō)明,以便本廠采用耐磨式機(jī)械密封。 五、ISG系列立式離心泵型號(hào)意義: 例如:ISG50-160(I)A ISG-立式單級(jí)管道離心泵 IRG-立式單級(jí)熱水管道離心泵 GRG-立式單級(jí)熱水管道離心泵 IHG-立式單級(jí)不銹鋼化工泵 YG-單級(jí)單吸管道油泵 50-泵進(jìn)、出口公稱直徑(mm) 160-葉輪名義外徑(mm) I-流量分類 A-葉輪經(jīng)第一次切割立式管道離心泵尺寸圖ISG系列立式管道離心泵性能參數(shù)表(1)ISG系列立式管道離心泵性能參數(shù)表(2)ISG系列立式管道離心泵性能參數(shù)表(3)ISG系列立式管道離心泵性能參數(shù)表(4)ISG系列立式管道離心泵性能參數(shù)表(5)ISG系列立式管道離心泵性能參數(shù)表(6)立式管道離心泵(故障原因及排除方法)故障現(xiàn)象 故障原因 排除方法 1、水泵不出水 a、進(jìn)出口閥門未打開(kāi),進(jìn)出管路堵塞,流道葉輪堵塞。b、電機(jī)運(yùn)行方向不對(duì),電機(jī)缺相轉(zhuǎn)速很慢。c、吸入管漏氣。d、泵沒(méi)灌滿液體,泵腔內(nèi)有空氣。e、進(jìn)口供水不足,吸程過(guò)高,底閥漏水。f、管路阻力過(guò)大,泵選型不當(dāng)。 a、檢查,去除堵塞物。b、調(diào)整電機(jī)方向,緊固電機(jī)接線。c、擰緊各密封面,排除漏氣。d、灌滿液體并打開(kāi)排氣閥,排盡空氣。e、停機(jī),檢查、調(diào)整(并網(wǎng)自來(lái)水管或帶吸程使用易出現(xiàn)此現(xiàn)象)。f、減少管路彎道,重新選泵。 2、水泵流量不足 a、先按1.原因檢查。b、管道、泵流道葉輪部分堵塞,水垢陳積,閥門開(kāi)度不足。c、電壓偏低。d、葉輪磨損。 a、先按1.排除。b、去除堵塞物,重新調(diào)整閥門開(kāi)度。c、穩(wěn)壓。d、更換葉輪。 3、功率過(guò)大 a、超過(guò)額定流量使用。b、吸程過(guò)高。c、泵軸承磨損。 a、調(diào)節(jié)流量,關(guān)小出口閥門。b、降低。c、更換軸承。 4、雜音振動(dòng) a、管路支撐不穩(wěn)。b、液體混有氣體。c、產(chǎn)生汽蝕。d、軸承損壞。e、電機(jī)超載發(fā)熱運(yùn)行。 a、穩(wěn)固管路。b、提高吸入壓力排氣。c、降低真空度。d、更換軸承。e、調(diào)整按5。 5、電機(jī)發(fā)熱 a、流量過(guò)大,超載運(yùn)行。b、碰擦。c、電機(jī)軸承損壞。d、電壓不足。 a、關(guān)小出口閥。b、檢查排除。c、更換軸承。d、穩(wěn)壓。 6、水泵漏水 a、機(jī)械密封磨損。b、泵體有砂孔或破裂。c、密封面不平整。d、安裝螺栓松懈。 a、更換。b、焊補(bǔ)或更換。c、修整。d、緊固。 同系列產(chǎn)品 MORE>> IHG型立式不銹鋼管道離心泵 ISWHB型臥式不銹鋼防爆管道離心泵 ISGB型立式防爆管道離心泵 IHGB型立式不銹鋼防爆管道離心泵