In choosing a centrifuge able to accept blood bags, the 9900 model is the best choice. The RS-7002 rotor and the RS-6602 rotor can spin 6 x 400mL quadruple blood bags. In addition, the 9900 is equipped with several functions designed for blood-bag centrifugation. For example, the acceleration and deceleration function (with 10 switching levels) is installed, while the super slow mode can avoid whirring up immediately before the centrifugal termination. If testing a large volume of samples with high g-force is the primary use, the 9900 model is the ideal choice. Some experiments, such as cell collection, require both large volume and high g-force. The S12510 rotor is able to spin 6 x 1,000mL bottles over 8,000xg. The rotor saves the total experiment time, reaching the maximum speed and in about three minutes. If complying with GMP (Good Manufacturing Practice) is required, the 9900 model is highly recommended. Various optional choices, such as PC connection, mounting a log printer, and a barcode reader, are available to meet stringent GMP requirements.
Maximum speed
6,000rpm
Maximum RCF
8,291xg
Maximum capacity
6,600mL
Control system
Microprocessor control, Induction motor (Brushless motor), Speed, RCF, Time, g-sec, Temperature, Acceleration & Deceleration, Memory (99 channels)
Abnormality detected display
Lid open, Imbalance, Over speed, Abnormally high temperature, Function for detecting an occurrence of electrical abnormality in motor, Inverter, Lid interlock sensor, Speed sensor, Temperature sensor
Acceleration/Deceleration
ten-level selectors
Speed setting
From 100 to 6,000rpm, 10rpm increments
Speed indication
Digital display, from 100 to 6,000rpm, 10rpm increments
RCF setting
From 10 to 8,291xg, 1xg increments
RCF indication
Digital display, from 0 to 8,291xg, 1xg increments
Integrator setting and indication
Digital display, from 1.00 to 9.99 x1010 g.sec
Timer setting and indication
Digital display, with Hold and Electric buzzer
from 1 sec. to 59 min. 59 sec., in 1 sec. increment setting from 1 min. to 99 hours 59 min., in 1 min. increments setting
Temperature setting and indication
Digital display, 0.1°C increments setting and indication
Ordinary model: from -20°C to 42°C
Brake system
Ten-level selectors
Power requirements
Single phase AC220V+10%-5%, 230V+10%-5%, 50/60Hz, 30A
In looking for a high capacity centrifuge ideal for middle throughput of blood separation, the 8920 model is the appropriate choice. The RS-730 swinging bucket rotor, which is the most popular rotor for the 8920, accepts 96 x 10mL tubes over 3,400Xg. In addition, the RS-730 swinging bucket rotor accepts sealing caps, which improve customers' safety against biocontamination. If separation of acid-fast bacteria is a primary use, look no further than the 8920 model. The RS-730 swinging bucket rotor accepts 28 x 50mL TC tubes over 3,700Xg with sealing caps, which improve customers' safety against biocontamination.
Swing bucket rotor
RS-730
Swinging Bucket Rotor · Autoclavable (121°C) · The rotor shown in the picture is attached with aluminum rectangular buckets (code no. S13215).
Max. 4,200rpm 3,750xg
Microtiter Plate Rotor
PT-21/PT-20
Microtiter Plate Rotor 6 x Microtiter plate · Autoclavable (121°C) · The 2 pieses of deep-well plate can also be used with the rotor.
Microtiter Plate Rotor 8 x Microtiter plate 2 x Deep-well plate + filtration plate · PT-89 is able to accept the plate whose height under 89 mm.
Max. 2,400rpm 1,080xg
PT-745S
Microtiter Plate rotor · The PT-745 is able to accept 12 x Microtiter plate or the plate whose height under 90 mm. · Ethanol can be settled for 3,100xg with the PT-745.
Max. 4,200rpm 3,100xg
Medium Capacity Fixed Angle Rotor
RA-288M2
Medium Capacity Fixed Angle Rotor 24 x 12mL
8,500rpm 9,690xg
RA-410M2
Medium Capacity Fixed Angle Rotor 8 x 15/50mL Conical (TC)